| поискавой системы для электроныых деталей |
|
GV2AP02 датащи(PDF) 42 Page - Schneider Electric |
|
|
|||||||||||||||||||||||||||||
GV2AP02 датащи(HTML) 42 Page - Schneider Electric |
|
42 / 48 page ![]() 41 Accessories for TeSys circuit-breakers (continued) (1) Description For circuit-breaker Unit reference Weight kg/lb Add-on blocks Visible isolation block (2) Max. number: 1 Mounted on front GV2L07…L22, GV2P07…P22 GV2AK00 0.150/ 0.331 Limiters Max. number: 1 Mounted on the top GV2P GV1L3 0.130/ 0.287 Separate GV2L/GV2P LA9LB920 0.320/ 0.705 Busbars 3-pole busbars 63 A, 2 tap links 45 mm/1.77 in. interval GV2L/GV2P GV2G245 0.036/ 0.079 54 mm/2.13 in. interval GV2L/GV2P GV2G254 0.038/ 0.084 72 mm/2.83 in. interval GV2L/GV2P GV2G272 0.042/ 0.093 3-pole busbars 63 A, 3 tap links 45 mm/1.77 in. interval GV2L/GV2P GV2G345 0.058/ 0.128 54 mm/2.13 in. interval GV2L/GV2P GV2G354 0.060/ 0.132 3-pole busbars 63 A, 4 tap links 45 mm/1.77 in. interval GV2L/GV2P GV2G445 0.077/ 0.170 54 mm/2.13 in. interval GV2L/GV2P GV2G454 0.085/ 0.187 72 mm/2.83 in. interval GV2L/GV2P GV2G472 0.094/ 0.207 3-pole busbars 63 A, 5 tap links 54 mm/2.13 in. interval GV2L/GV2P GV2G554 0.100/ 0.220 Terminal blocks For supplying one or more busbars GV2Gppp Connection at the top GV2L/GV2P GV1G09 0.040/ 0.088 Can take the GV1L3 limiter GV2P GV2G05 0.115/ 0.253 Protective end cover For busbar output awaiting extension (sold in lots of 5) GV2L/GV2P GV1G10 0.005/ 0.0 11 Cover for terminal block For mounting in modular distribution boards (sold in lots of 10) GV2L/GV2P LA9E07 0.005/ 0.011 Adapter Large spacing adapter UL 508 type E GV2P07…P022 GV2GH7 0.040/ 0.088 External controls External control Max. enclosure depth 290 mm/11.41 in. Visual OFF indication Red handle, yellow front plate, IP 54 Can be locked with padlock (not supplied) GV2L, GV2P GV2AP02 0.200/ 0.441 External control Max. enclosure depth 290 mm/11.41 in. No visual ON/OFF indication Does not lock the door or plug-in base opening control mechanism in the ON position Color: RAL 7016, IP 54 GV2L, GV2P GV2AP04 0.104/ 0.229 External control Max. enclosure depth 390 mm/15.35 in. Includes: A handle LU9AP1p, a rod 260 mm/10.24 in. maximum, a bracket and an adapter. Visual OFF indication Red handle, yellow front plate, IP 54 Can be locked with padlock (not supplied) GV3L, GV3P GV3AP02 0.294/ 0.648 Padlocking device Padlocking device Can take 4 padlocks (not supplied) ∅ 6 mm/0.24 in. max. GV2L, GV2P GV3L, GV3P GV2V03 0.092/ 0.203 (1) For a detailed description and other accessories for circuit-breakers, please refer to the "Motor starter solutions - Control and protection components" catalog or visit www.schneider-electric.com. (2) 3 poles isolated upstream of GV2L and GV2P circuit-breakers. Combinations (continued) Variable speed drives Altivar Machine ATV320 Accessories for TeSys circuit-breakers Example of GV2/ATV320 direct mounting in an enclosure: GV2L circuit-breakers + GV2454 and GV2G05 accessories + ATV320U15N4B drives |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |