| поискавой системы для электроныых деталей |
|
OVR40150 датащи(PDF) 6 Page - ABB |
|
|
|||||||||||||||||||||||||||||
OVR40150 датащи(HTML) 6 Page - ABB |
|
6 / 62 page ![]() Surge Pr otective Devices 16.4 Low Voltage Products & Systems 1SXU000023C0202 Rev. A ABB Inc. • 888-385-1221 • www.abb.us/lowvoltage 16 16 Imc Note: Common mode overvoltages affect all grounding systems. SPD terminology 8/20 wave: Current waveform which passes through equipment when subjected to an overvoltage (low energy). Type 2 surge protective device (SPD) Permanently connected SPDs intended for installation on the load side of the service equipment overcurrent device, including SPDs located at a branch panel. It has successfully passed testing to the standard with the 8/20 wave (class II test). Metal oxide varistor (MOV) A varistor is an electronic component with a “diode like” nonlinear current-voltage characteristic, used to protect circuits against excessive transient voltages. Most commonly composed of metal oxides. Maximum continuous operating voltage (MCOV, Uc) The maximum designated root mean square (rms) value of power frequency voltage that may be applied continuously between the terminals of the SPD. Nominal discharge current (In) Peak current value of an 8/20 waveform which the SPD is rated for based on the test program. Maximum discharge current (Imax) Peak current value of an 8/20 waveform which can be safely discharged by the SPD, with an amplitude complying with the class II operating test sequence. Imax > In Short circuit current rating (SCCR) Maximum symmetrical fault current, at rated voltage, that the SPD can withstand without sustaining damage that exceeds acceptable criteria or creates a hazardous operating condition. Voltage protection rating (VPR) The value of the VPR is determined as the nearest highest value, taken from Table 63.1 of ANSI/UL 1449 3rd Edition, to the measured limiting voltage determined during the transient voltage surge suppression test using the combination wave generator at a setting of 6kV, 3kA. Voltage protection level (Up or Ures) The voltage let through by the SPD while diverting surge current to ground must not exceed the voltage withstand value of the equipment connected downstream. General information Terminology of SPD electrical characteristics Imd Ph N V A Time (µs) Time (µs) Residual Voltage Shaved Peak * Graph depicts an 8/20µs wave Notes: Test wave 8/20µs according to IEEE # C62.62-200/UL 1449 The first number corresponds to the time from 10% to 90% of its peak value (8µs). The second number corresponds to the time taken for the wave to descend to 50% of its peak value (20µs). Common mode and / or differential mode protection Common mode Common mode overvoltages appear between the live conductors and ground, e.g. phase/ground or neutral/ground. A live conductor not only refers to the phase conductors but also to the neutral conductor. This overvoltage mode destroys equipment connected to ground (class I equipment) and also equipment not connected to ground (class II equipment) which is located near a grounded mass and which does not have sufficient electrical isolation (a few kilovolts). Class II equipment not located near a grounded mass is theoretically protected from this type of attack. Differential mode Differential mode overvoltages circulate between live conductors: phase/phase or phase/neutral. These overvoltages have a potentially high damaging effect for all equipment connected to the electrical network, especially ‘sensitive’ equipment. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |