| поискавой системы для электроныых деталей |
|
CDC906 датащи(PDF) 19 Page - Texas Instruments |
|
|
|
|||||||||||||||||||||||||||||
CDC906 датащи(HTML) 19 Page - Texas Instruments |
|
19 / 39 page ![]() www.ti.com CDC906 SCAS828 – SEPTEMBER 2006 Byte 25, Bit [3:0]: SSC Modulation Frequency Selection in the Range of 30 kHz 60 kHz(1) fvco [MHz] Modulation FSSC3 FSSC2 FSSC1 FSSC0 Default(2) Factor 100 110 120 130 140 150 160 167 0 0 0 0 5680 17.6 19.4 21.1 22.9 24.6 26.4 28.2 29.4 0 0 0 1 5412 18.5 20.3 22.2 24.0 25.9 27.7 29.6 30.9 0 0 1 0 5144 19.4 21.4 23.3 25.3 27.2 29.2 31.1 32.5 0 0 1 1 4876 20.5 22.6 24.6 26.7 28.7 30.8 32.8 34.2 0 1 0 0 4608 21.7 23.9 26.0 28.2 30.4 32.6 34.7 36.2 0 1 0 1 4340 23.0 25.3 27.6 30.0 32.3 34.6 36.9 38.5 0 1 1 0 4072 24.6 27.0 29.5 31.9 34.4 36.8 39.3 41.0 0 1 1 1 3804 26.3 28.9 31.5 34.2 36.8 39.4 42.1 43.9 fmod [kHz] 1 0 0 0 3536 28.3 31.1 33.9 36.8 39.6 42.4 45.2 47.2 1 0 0 1 3286 30.4 33.5 36.5 39.6 42.6 45.6 48.7 50.8 Yes 1 0 1 0 3000 33.3 36.7 40.0 43.3 46.7 50.0 53.3 55.7 1 0 1 1 2732 36.6 40.3 43.9 47.6 51.2 54.9 58.6 61.1 1 1 0 0 2464 40.6 44.6 48.7 52.8 56.8 60.9 64.9 67.8 1 1 0 1 2196 45.5 50.1 54.6 59.2 63.8 68.3 72.9 76.0 1 1 1 0 1928 51.9 57.1 62.2 67.4 72.6 77.8 83.0 86.6 1 1 1 1 1660 60.2 66.3 72.3 78.3 84.3 90.4 96.4 100.6 (1) The PLL has to be bypassed (turned off) when changing SSC Modulation Frequency Factor on-the-fly. This can be done by following programming sequence: bypass PLL2 (Byte 3, Bit 6 = 1); write new Modulation Factor (Byte 25); re-activate PLL2 (Byte 3, Bit 6 = 0). (2) Unless customer specific setting. Byte 25, Bit [6:4]: SSC Modulation Amount (1) SSC2 SSC1 SSC0 Function Default(2) 0 0 0 SSC Modulation Amount 0% = SSC bypass for PLL(3) Yes 0 0 1 SSC Modulation Amount ±0.1% (center spread) 0 1 0 SSC Modulation Amount ±0.25% (center spread) 0 1 1 SSC Modulation Amount ±0.4% (center spread) 1 0 0 SSC Modulation Amount 1% (down spread) 1 0 1 SSC Modulation Amount 1.5% (down spread) 1 1 0 SSC Modulation Amount 2% (down spread) 1 1 1 SSC Modulation Amount 3% (down spread) (1) The PLL has to be bypassed (turned off) when changing SSC Modulation Amount on-the-fly. This can be done by following programming sequence: bypass PLL2 (Byte 3, Bit 6 = 1); write new Modulation Amount (Byte 25); re-activate PLL2 (Byte 3, Bit 6 = 0). (2) Unless customer specific setting. (3) If SSC bypass is selected, SSC circuitry of PLL2 is powered-down and the SSC output is reset to logic low. The non-SSC output of PLL2 is not affected by this mode and can still be used. 19 Submit Documentation Feedback |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |