17 / 24 page ![]() MP5048 – 60V, 15A, 7mΩ RDS(ON) HOT-SWAP INTELLI-FUSE SOLUTION MP5048 Rev. 1.1 www.MonolithicPower.com 17 4/30/2021 MPS Proprietary Information. Patent Protected. Unauthorized Photocopy and Duplication Prohibited. © 2021 MPS. All Rights Reserved. Insertion Delay MP5048 UVLO VOUT ON VCC VCLREF SS Limit VCLREF_NORM t Figure 13: MP5048 SS Current Limit If VOUT drops below 90% of VIN, the current limit reference is clamped to VBE (660mV with a negative temperature coefficient), and the thermal shutdown threshold is 153°C. If the CS limit reference configuration current is 8 μA, then the external CLREF voltage depends on the CLREF external resistor. If the external CLREF voltage drops below the clamp voltage (VCLREF_CLAMP), the actual current limit reference voltage is determined by the external CLREF voltage. If VOUT ≥ 90% of VIN, the internal maximum current limit reference voltage is disabled. The CS limit reference configuration current ranges between 8 μA and 26μA (8μA + 18μA), and CS is limited by the CLREF ’s externally configured value (typically limited to 2V). If VCS exceeds the SS limit during start-up, the power FET gate voltage is regulated to hold the FET current constant. If the power FET remains on while VOUT remains below 90% of VIN within the 200ms maximum soft-start time, the power FET shuts down when the 200ms time ends. If the value of the SS limit is higher, the power FET start-up instantaneous loss is large and a thermal shutdown is triggered before the 200ms time ends. In this case, FAULT is driven low (see Figure 14). t VGS VOUT FAULT ON VCS 600mV Maximum SS time 200ms VGS_TH VSS_LIMT Thermal Shutdown Figure 14: Failed Start-Up Within 200ms If VOUT drops below 20% of VIN during start-up and the power FET current is regulated by VSS_LIMIT for the start-up SCP timer, the power FET turns off with a fault latch condition, and FAULT is pulled low. Current Limit During Normal Operation When the MP5048 detects that start-up has finished, the part enters normal operation. During normal operation, once VCS (which is configured by an external resistor) exceeds the normal CLREF threshold, the internal circuit regulates the gate voltage to hold the power FET constant. To limit the current, the gate-to-source voltage must be regulated from 5V to about VTH. The typical response time is about 14µs. The output current may have a small overshoot during this time period. If the current limit is reached, the internal fault timer starts. If the output current falls below the current limit threshold before the end of the over- current protection (OCP) fault timeout period, the MP5048 resumes normal operation. If the current exceeds the fault timeout period, the power FET latches off and FAULT is pulled low. The desired current limit during normal operation is a function of CS ’s external resistor (RCS). The MP5048 current limit value can exceed the normal maximum load current, allowing tolerances in the current-sense value. The current limit can be estimated with Equation (2): CS CS CLREF_NORM LIMIT R G V I (2) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |