| поискавой системы для электроныых деталей |
|
THDC датащи(PDF) 1 Page - Greystone Energy Systems Inc. |
|
|
|||||||||||||||||||||||||||||
THDC датащи(HTML) 1 Page - Greystone Energy Systems Inc. |
|
1 / 2 page ![]() GREYSTONE HAS AN ISO 9001 REGISTERED QUALITY SYSTEM FLEXIBLE COPPER DUCT AVERAGE HIGH LIMIT THERMOSTAT THDC SERIES CABLE GLAND FITTING THREAD ADAPTER 1/2” NPT TO M16 ACCESSORIES - INCLUDED WITH F STYLE ENCLOSURE PRODUCT DESCRIPTION The multi point duct average high limit thermostat incorporates several precision thermistor temperature sensors and provides a Form C relay output (NO/NC) with an adjustable setpoint. The sensor is encapsulated in a 7.94 mm (0.3125”) OD, soft copper probe and is available in various lengths (see ordering chart). All probes provide excellent heat transfer, fast response and resistance to moisture penetration. A Polycarbonate enclosure with a hinged and gasketed cover is provided for ease of installation. TYPICAL INSTALLATION For complete installation and wiring details, please refer to the product installation instructions. The duct average probes are installed through a hole in the side of the duct to monitor an average temperature within the duct. Select a probe length that allows for criss-crossing the duct multiple times. Install the probes in a straight section of duct at a suitable distance downstream from any heating, cooling or humidification devices. The enclosure provides mounting tabs for ease of installation. POWER SUPPLY 12 to 28 Vac/dc SENSOR ACCURACY ±0.2°C, 0 to 70°C (±0.36°F, 32 to 158°F) PROBE SENSING RANGE -20 to 60°C (-4 to 140°F) PROBE MATERIAL Soft copper PROBE DIAMETER 7.94mm (0.3125”) STANDARD LENGTHS 1800mm, 3600mm, 6100mm, 7300mm (6’, 12’, 20’, 24’) WIRE MATERIAL FT-6 plenum rated cable CONSUMPTION 50 mA max RELAY CONTACTS SPDT, Form C contacts (N.O. and N.C.) 5 Amps @ 30 Vdc/250 Vac resistive 1.5 Amps @ 30 Vdc/250 vac inductive RELAY ACTION Activates on temperature rise SETPOINT OPERATION Single-turn knob-pot on PCB ADJUSTABLE SETPOINT 38 to 60°C (100 to 140°F) TEMPERATURE DIFFERENTIAL Low: 1.1°C (2°F) Mid: 2.8°C (5°F) High: 5.6°C (10°F) Jumper selectable TEMPERATURE SENSOR 10,000Ω curve matched precision thermistor SENSOR ACCURACY ±0.2°C, 0 to 70°C (±0.36°F, 32 to158°F) OPERATING CONDITIONS -10 to 50°C (14 to 122°F), 5 to 95 %RH, non-condensing STORAGE CONDITIONS -30 to 70°C (-22 to 158°F), 5 to 95 %RH, non-condensing WIRING CONNECTIONS Screw terminal block (14 to 22 AWG) ENCLOSURE B: Grey polycarbonate UL94-V0, IP65 (NEMA 4X) F: Same as B with thread adapter (1/2” NPT to M16) and cable gland fitting COUNTRY OF ORIGIN Canada SPECIFICATIONS 112.5 mm 4.43" 99.7 mm 3.93" Various Probe Lengths See Specifications 116.5 mm 4.58" 0.5" NPT Foam Gasket Soft Copper 53.7 mm 2.11" 7.94 mm 0.312" |
Аналогичный номер детали - THDC |
|
Аналогичное описание - THDC |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |