2 / 5 page

PJ31002
Tone Ringer For Telephone Set
2-5
2002/01.rev.A
( NOT E 1 )
Supply initiation voltage is the value of DC supply voltage required to start the tone
ringer oscillation.
( NOT E 2 )
Sustaining voltage is the value of DC supply voltage required to maintain oscillation.
( NOT E 3 )
Oscillator frequency is determined by the following equations :
fL = 1 / ( 1.234 * R1 * C1 )
Hz
fH1 = 1 / ( 1.515 * R2 * C2 )
Hz
fH2 = 1.24 * fH1
Hz
( NOT E 4 )
Ringing start voltage is the value of AC supply voltage required to start the tone ringer
ringing in FIG.3
( NOT E 5 )
T his product is not designed for protection against radioactive rays.
( NOT E 6 )
All data and specifications are subject to change without notice.
Figure 2. Block Diagram