| поискавой системы для электроныых деталей |
|
PM9904BPD датащи(PDF) 5 Page - Sames |
|
|
|||||||||||||||||||||||||||||
PM9904BPD датащи(HTML) 5 Page - Sames |
|
5 / 22 page ![]() sames sames PM9904BPD 5/22 Figure 6: Interrupt flow diagram Reg 0 add to Integrator Reg 4 add to Integrator Reg 8 add to Integrator Pulse threshold Integrator zero Pulse LED Threshold value subtracted Pulse Generated from integrator Figure 5: Implementation of an overflow integrator http://www.sames.co.za where: Vnom is the mains voltage and correspond to 14µA in the voltage inputs of the SA9904B. Imax is the maximum mains current to be measured and correspond to 16µA on the current inputs of the SA9904B. The pulse rate required for a meter is usually expressed in pulses/kWh. A single pulse on the LED is mostly a fraction of a kWh and is converted to energy in Ws/pulse Energy per LED pulse is (Ws/pulse): Epp energy = 1000 x 3600 / Mpr where: Epp is energy per LED pulse Mpr is the meter pulse rate or meter constant in pulses/kWh The threshold is calculated by dividing the energy represented by a LED pulse by the energy per register count. Active energy threshold = Epp / Epc The threshold is thus the amount of energy to be measured (accumulated / integrated) by the meter before a LED pulse is generated. Meter creep current For the SA9904B meter creep must be taken care of in software. From the explanation above on how to generate pulses, the meter must also be prevented from pulsing in cases where the energy measured is less than the creep threshold as per the meter specification. The creep current is defined as the limit for measured energy, any energy less than the creep threshold is discarded, and energy above the creep threshold is measured. The simplest way to implement the creep threshold is to relate it to the time between meter pulses. If the time between pulses is more than the limit, the energy accumulator is cleared. Pulse rate of meter at rated conditions (Hz): Rf = ( Vnom x Imax / 1000 ) x ( Mpr / 3600 ) where: Vnom is the mains voltage and correspond to 14µA in the voltage inputs. Imax is the maximum mains current to be measured and correspond to 16µA on the current inputs of the device. Mpr is the meter pulse rate in pulses/kWh. Creep threshold time (s): Ct = 1/(Cc / Imax) x Rf where: Cc is the specified creep current; energy below this value is discarded. Imax is the maximum mains current to be measured and correspond to 16µA on the current inputs of the device. Rf is the rated current frequency. The flow diagram (figure 6) for the timer interrupt shows how the time between pulses is measured, if the time since the last pulse is more than the time measured, the integrator is reset and a new count down is started. If LED On If LED ON Timer = 0 Switch LED off Decrement creep timer If creep timer = 0 Decrement LED ON timer If creep timer > 0 Load creep timer Reset integrator Yes Yes Yes Yes No No Exit Interrupt Start Timer Interrupt If LED On If LED ON Timer = 0 Switch LED off Decrement creep timer If creep timer = 0 Decrement LED ON timer If creep timer > 0 Load creep timer Reset integrator Yes Yes Yes Yes No No Exit Interrupt Start Timer Interrupt No |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |