| поискавой системы для электроныых деталей |
|
AM452 датащи(PDF) 14 Page - WOLFSPEED, INC. |
|
|
|||||||||||||||||||||||||||||
AM452 датащи(HTML) 14 Page - WOLFSPEED, INC. |
|
14 / 21 page ![]() AM452 – Voltage-to-current transducer IC with a differential input Analog Microelectronics GmbH An der Fahrt 13, D – 55124 Mainz February 2008 - Rev 1.2 - Page 14/21 Phone: +49 (0)6131/91 073-0 Fax: +49 (0)6131/91 073-30 Internet: http://www.analogmicro.de Email: info@analogmicro.de 9. For applications where IOUT min > 0mA (e.g. 4mA) in both 2- and 3-wire applications the following condition applies to the IA input values: min max . . OUT OUT IA OS IA FS I I V V ≥ , where VFS.IA is the maximum input signal and VOS.IA the positive offset at the input IA. 10. If signal source and/or input amplifier IA have a negative offset this can be compensated for using corrective voltage VZA and a suitable voltage divider (R6 and R7; see Figure 2). DIMENSIONING Two possible dimensioning methods are suggested here. Dimensioning the external components according to the equations given in the data sheet Dimensioning according to the equations given in the data sheet enables all modules to be used, making it possible for the setup to be adapted to suit the most diverse application requirements. As a rule the offset of the AM452 input signal must be taken into account. If an input signal offset is present and an offset current of IOUT min > 0mA is required, the following boundary condition then applies: min max . . OUT OUT IA OS IA FS I I V V ≥ , where VFS.IA is the maximum input signal and VOS.IA the positive offset at the input IA (see: chapter before). Should the signal source have a negative offset, the offset can be set via pin 13 (ZA) and voltage divider R6 and R7 (see Figure 2). Equation (1) forms the basis for all other equations in this particular case. If the offset is negligible, Equations (9) and (10) apply. See the following applications for further details. Dimensioning AM452's external components using an Excel spreadsheet AM452's external components can also be dimensioned with the help of Excel spreadsheet Kali_AM452.xls when the input signal is positive (see [3]). The algorithm is such that the offset output current of 4mA can only be set via pin 13 (ZA) of the zero adjust stage. The SET stage is not active. The full-scale output current is set to 20mA using the OP1 gain setting. The calibration process is also based on the condition that the output signal should be a 4...20mA current loop signal in 2-wire operation. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |