| поискавой системы для электроныых деталей |
|
DP83848M датащи(PDF) 21 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
DP83848M датащи(HTML) 21 Page - National Semiconductor (TI) |
|
21 / 72 page ![]() 21 www.national.com The Start code is indicated by a <01> pattern. This assures the MDIO line transitions from the default idle line state. Turnaround is defined as an idle bit time inserted between the Register Address field and the Data field. To avoid con- tention during a read transaction, no device shall actively drive the MDIO signal during the first bit of Turnaround. The addressed DP83848M/J drives the MDIO with a zero for the second bit of turnaround and follows this with the required data. Figure 4 shows the timing relationship between MDC and the MDIO as driven/received by the Sta- tion (STA) and the DP83848M/J (PHY) for a typical register read access. For write transactions, the station management entity writes data to the addressed DP83848M/J thus eliminating the requirement for MDIO Turnaround. The Turnaround time is filled by the management entity by inserting <10>. Figure 5 shows the timing relationship for a typical MII reg- ister write access. 3.2.3 Serial Management Preamble Suppression The DP83848M/J supports a Preamble Suppression mode as indicated by a one in bit 6 of the Basic Mode Status Register (BMSR, address 01h.) If the station management entity (i.e. MAC or other management controller) deter- mines that all PHYs in the system support Preamble Sup- pression by returning a one in this bit, then the station management entity need not generate preamble for each management transaction. The DP83848M/J requires a single initialization sequence of 32 bits of preamble following hardware/software reset. This requirement is generally met by the mandatory pull-up resistor on MDIO in conjunction with a continuous MDC, or the management access made to determine whether Pre- amble Suppression is supported. While the DP83848M/J requires an initial preamble sequence of 32 bits for management initialization, it does not require a full 32-bit sequence between each subse- quent transaction. A minimum of one idle bit between man- agement transactions is required as specified in the IEEE 802.3u specification. Table 6. Typical MDIO Frame Format MII Management Serial Protocol <idle><start><op code><device addr><reg addr><turnaround><data><idle> Read Operation <idle><01><10><AAAAA><RRRRR><Z0><xxxx xxxx xxxx xxxx><idle> Write Operation <idle><01><01><AAAAA><RRRRR><10><xxxx xxxx xxxx xxxx><idle> Figure 4. Typical MDC/MDIO Read Operation Figure 5. Typical MDC/MDIO Write Operation MDC MDIO 00 0 11 110 0 00 000 (STA) Idle Start Opcode (Read) PHY Address (PHYAD = 0Ch) Register Address (00h = BMCR) TA Register Data Z MDIO (PHY) Z Z Z 0 0 0 1 1 0 0 0 1 0 0 0000 0 0 Z Idle Z Z MDC MDIO 00 0 11 11 0 0 0 0 000 (STA) Idle Start Opcode (Write) PHY Address (PHYAD = 0Ch) Register Address (00h = BMCR) TA Register Data Z 0 0 0 0 00 0 0 0 0 0 000 Z Idle 10 0 0 Z Z |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |