ADF4193BCPZ датащи(PDF) 19 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADF4193BCPZ датащи(HTML) 19 Page - Analog Devices |
|
19 / 28 page ![]() ADF4193 Rev. B | Page 19 of 28 CHARGE PUMP REGISTER (R4) DB23 0 DB22 0 DB21 0 DB20 0 DB19 0 DB18 0 DB17 0 DB16 0 DB15 0 DB14 1 DB13 C9 DB12 C8 DB11 C7 DB10 C6 DB9 C5 DB8 C4 DB7 C3 DB6 C2 DB5 C1 DB4 F2 DB3 F1 DB2 C3 (1) DB1 C2 (0) DB0 C1 (0) 9-BIT TIMEOUT COUNTER RESERVED CONTROL BITS TIMER SELECT 0 0 1 1 F2 0 1 0 1 F1 SW1/SW2 SW3 ICP NOT USED TIMER SELECT C9 0 0 0 0 . . . 1 1 1 1 C8 0 0 0 0 . . . 1 1 1 1 C7 0 0 0 0 . . . 1 1 1 1 .......... .......... .......... .......... .......... .......... .......... .......... .......... .......... .......... C3 0 0 0 0 . . . 1 1 1 1 C2 0 0 1 1 . . . 0 0 1 1 C1 0 1 0 1 . . . 0 1 0 1 TIMEOUT COUNTER 0 1 2 3 . . . 508 509 510 511 xPFD CYCLES 0 4 8 12 . . . 2032 2036 2040 2044 DELAY µs1 0 0.15 0.30 0.46 . . . 78.15 78.30 78.46 78.61 1DELAY WITH 26MHz PFD Figure 33. Charge Pump Register (R4) Reserved Bits Bit DB23 to Bit DB14 are reserved and should be set to hex code 001 for normal operation. 9-Bit Timeout Counter These bits are used to program the fast lock timeout counters. The counters are clocked at one-quarter the PFD reference frequency, therefore, their time delay scales with the PFD frequency according to Delay(s) = (Timeout Counter Value × 4)/(PFD Frequency) For example, if 35 were loaded with timer select (00) with a 13 MHz PFD, then SW1/SW2 would be switched after (35 × 4)/13 MHz = 10.8 μs Timer Select These two address bits select the timeout counter to be programmed. Note that to set up the ADF4193 correctly requires setup of these three timeout counters; therefore, three writes to this register are required in the initialization sequence. Table 6 shows example values for a GSM Tx synthesizer with a 60 kHz final loop BW. See the Applications section for more information. Table 6. Recommended Values for a GSM Tx LO Timer Select Timeout Counter Value Time (μs) with PFD = 13 MHz 10 ICP 28 8.6 01 SW1/2 35 10.8 00 SW3 35 10.8 On each write to R0, the timeout counters start. Switch SW3 closes until the SW3 counter times out. Similarly, switches SW1/SW2 close until the SW1/SW2 counter times out. When the ICP counter times out, the charge pump current is ramped down from 64× to 1× in six binary steps. It is recommended that the SW1, SW2, and SW3 timeout counter values are set equal to the ICP timeout counter value plus 7, as in the example of Table 6. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |