24 / 42 page ![]() PicoVNA® 100 Series vector network analyzers Recommended configurations using automated E-Cal SOLT calibration standards Primary DUT interface Select accessory grade Required test leads Required manual calibration kits Supported measurement and calibration modes Also suited to DUTs… Universal capability. Dual-port devices or any single-port device with male or female or male and female ports Standard SMA test leads 2x TA336 SMA male port 2x TA343 SMA(f-f) port adaptor 1x TA518 SOLT-AUTO-M and 1x TA519 SOLT-AUTO-F* All dual-port calibration modes and S-parameters Use and include within calibration: 1) A test port adaptor to address insertable dual- port devices**. 2) Both port adaptors to address dual male port non-insertable devices. Premium PC3.5 test leads 2x TA338 PC3.5 male port 2x TA341 PC3.5(f-f) port adaptor Alternatively using 1x automated E-Cal calibration standard … Dual-port non- insertable devices or any single female port device Standard SMA test leads 2x TA336 SMA male port 1x or 2x TA343 SMA(f-f) adaptor 1x TA519 SOLT-AUTO-F All dual-port calibration modes and S-parameters Use and include within calibration a test port adaptor to address insertable dual-port devices or single-port device of opposing gender**. Note that opposing gender dual-port non- insertable devices can be addressed by adding and de-embedding a further port adaptor.***. Premium PC3.5 test leads 2x TA338 PC3.5 male port 1x or 2x TA341 PC3.5(f-f) adaptor Dual-port non- insertable devices or any single male port device Standard SMA test leads 2x TA337 SMA female port 1x or 2x TA342 SMA(m-m) adaptor 1x TA518 SOLT-AUTO-M Premium PC3.5 test leads 2x TA339 PC3.5 female port 1x or 2x TA342 SMA(m-m) adaptor * This automated dual E-Cal SOLT configuration is available with discount. Please see TA520 on the ordering information page. ** To calibrate use the characterized and polarized through adaptor supplied with your E-Cal standard. The PicoVNA E-Cal calibration wizard guides this setup. *** With only one calibration kit it is not possible to calibrate after two-port gender adaptations. Purchase a second E-Cal calibration kit of opposing gender for full calibration after two-port adaptions. Alternatively, once a non-insertable calibration has been performed, it is possible to measure the second port adaptor and de-embed its error. A third option is to use reference plane shift and/or normalization for a lesser correction of adaptor errors. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |