| поискавой системы для электроныых деталей |
|
PQ201 датащи(PDF) 26 Page - Pico Technology Ltd. |
|
|
|||||||||||||||||||||||||||||
PQ201 датащи(HTML) 26 Page - Pico Technology Ltd. |
|
26 / 39 page ![]() PicoScope® 6000E Series Features • Up to 1.3 GHz probe bandwidth • Click-to-fit convenience • Super light flexible cable • Control capture start and stop using a button on the probe • Connects directly to PicoScope 6000E Series oscilloscopes with the Intelligent Probe Interface • Powered by the oscilloscope, eliminating separate power supplies and interface boxes • Automatic probe detection and unit scaling • LED status indicator A3000 Series active probes with Intelligent Probe Interface The Pico A3000 Series are high-impedance active oscilloscope probes. They have been designed to have minimal impact on the signal being probed with optimal signal transfer to the PicoScope 6000E Series through the intelligent probe interface. Their ergonomic design allows for comfortable handheld use with the addition of a button to start and pause capturing in PicoScope 6. The intelligent probe interface powers the probe from the scope and automatically sets the scope’s scaling and input impedance to match the probe. With an input resistance of 1 MΩ and capacitance of 0.9 pF, these active probes offer high input impedance up to 1 GHz. These characteristics make this probe the most versatile for many of your day-to-day measurements. Specifications A3076 A3136 Probe bandwidth (−3 dB) 750 MHz 1.3 GHz Nominal system bandwidth (−3 dB) 750 MHz (with 750 MHz PicoScope 6000E models) 1 GHz (with 1 GHz PicoScope 6000E models) Input resistance 1 MΩ +3%, −0% Input capacitance 0.9 pF nominal Attenuation 10:1 DC gain accuracy (probe) ±3% of signal DC gain accuracy (with PicoScope 6000E Series) ±4% of signal (nominal) DC offset accuracy (with PicoScope 6000E Series) ±(1% of full scale + 4 mV) (nominal) Offset accuracy can be improved by using the “zero offset” function in PicoScope 6. Input dynamic range ±5 V (DC + AC peak) DC offset range ±10 V Measurable voltage window ±15 V (DC + AC peak) Maximum non-destructive input voltage ±30 V (DC + AC peak) derated with frequency above 250 MHz Noise 2.5 mV RMS nominal referred to probe input Probe button Control start/stop capture in PicoScope 6 Cable length 1.2 m Optional accessories |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |