| поискавой системы для электроныых деталей |
|
5000D датащи(PDF) 18 Page - Pico Technology Ltd. |
|
|
|||||||||||||||||||||||||||||
5000D датащи(HTML) 18 Page - Pico Technology Ltd. |
|
18 / 22 page ![]() PicoScope® 5000D Series oscilloscopes PicoScope 5000D Series Technical Specifications PicoScope 5242D and 5242D MSO 2-channel, 60 MHz PicoScope 5442D and 5442D MSO 4-channel, 60 MHz PicoScope 5243D and 5243D MSO 2-channel, 100 MHz PicoScope 5443D and 5443D MSO 4-channel, 100 MHz PicoScope 5244D and 5244D MSO 2-channel, 200 MHz PicoScope 5444D and 5444D MSO 4-channel, 200 MHz Maximum post-trigger delay Zero to 4 billion samples, settable in 1 sample steps (delay range on fastest timebase of 0 to 4 s in 1 ns steps) Trigger rearm time 8-bit mode, typical: 1 μs on fastest timebase 8 to 12-bit modes: < 2 μs max on fastest timebase 14 to 16-bit modes: < 3 μs max on fastest timebase Maximum trigger rate 10 000 waveforms in a 10 ms burst, 8-bit mode External trigger input – not MSO models Connector type Front panel BNC(f) Trigger types Edge, pulse width, dropout, interval, logic Input characteristics 1 MΩ ±1% || 14 pF ±1.5 pF Bandwidth 60 MHz 100 MHz 200 MHz Threshold range ±5 V External trigger threshold accuracy ±1% of full scale External trigger sensitivity 200 mV peak to peak Coupling DC Overvoltage protection ±100 V (DC + AC peak) Function generator Standard output signals Sine, square, triangle, DC voltage, ramp up, ramp down, sinc, Gaussian, half-sine Pseudorandom output signals White noise, selectable amplitude and offset within output voltage range. Pseudorandom binary sequence (PRBS), selectable high and low levels within output voltage range, selectable bit rate up to 20 Mb/s Output frequency 0.025 Hz to 20 MHz Sweep modes Up, down, dual with selectable start / stop frequencies and increments Triggering Can trigger a counted number of waveform cycles or frequency sweeps (from 1 to 1 billion) from the scope trigger, external trigger (non-MSO models only) or from software. Can also use the external trigger to gate the signal generator output. Output frequency accuracy Oscilloscope timebase accuracy ± output frequency resolution Output frequency resolution < 0.025 Hz Output voltage range ±2 V Output voltage adjustments Signal amplitude and offset adjustable in approx 0.25 mV steps within overall ±2 V range Amplitude flatness < 1.5 dB to 20 MHz, typical DC accuracy ±1% of full scale SFDR > 70 dB, 10 kHz full scale sine wave Output resistance 50 Ω ±1% Connector type BNC(f) Overvoltage protection ±20 V |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |