| поискавой системы для электроныых деталей |
|
ADT7482ARMZ датащи(PDF) 12 Page - Analog Devices |
|
|
|||||||||||||||||||||||||||||
ADT7482ARMZ датащи(HTML) 12 Page - Analog Devices |
|
12 / 24 page ![]() ADT7482 Rev. 0 | Page 12 of 24 REGISTERS The registers in the ADT7482 are 8-bits wide. These registers are used to store the results of remote and local temperature measurements and high and low temperature limits and to configure and control the device. A description of these registers follows. ADDRESS POINTER REGISTER The address pointer register itself does not have, or require, an address, as the first byte of every write operation is automatically written to this register. The data in this first byte always contains the address of another register on the ADT7482, which is stored in the address pointer register. It is to this register address that the second byte of a write operation is written to or to which a subsequent read operation is performed. The power-on default value of the address pointer register is 0x00. Therefore, if a read operation is performed immediately after power-on, without first writing to the address pointer, the value of the local temperature is returned, since its register address is 0x00. CONFIGURATION REGISTERS There are two configuration registers used to control the operation of the ADT7482. Configuration 1 register is at Address 0x03 for reads and Address 0x09 for writes. See Table 9 for details regarding the operation of this register. Configuration 2 Register is at Address 0x24 for both reads and writes. Setting Bit 7 of this register locks all lockable registers. The affected registers can only be modified if the ADT7482 is powered down and powered up again. See Table 16 for a list of the registers affected by the lock bit. TEMPERATURE VALUE REGISTERS The ADT7482 has five registers to store the results of local and remote temperature measurements. These registers can only be written to by the ADC and can be read over the SMBus. • The local temperature value register is at Address 0x00. • The Remote 1 temperature value high byte register is at Address 0x01; the Remote 1 low byte register is at Address 0x10. • The Remote 2 temperature value high byte register is at Address 0x30; the Remote 2 low byte register is at Address 0x33. • The Remote 2 temperature values can be read from Addresses 0x01 for the high byte and Address 0x10 for the low byte if Bit 3 of Configuration Register 1 is set to 1. • To read the Remote 1 temperature values, set Bit 3 of Configuration Register 1 to 0. • The power-on default for all five registers is 0x00. Table 9. Configuration 1 Register (Read Address = 0x03, Write Address = 0x09) Bit Mnemonic Description 7 Mask Setting this bit to 1 masks all ALERTs on the ALERT pin. Default = 0 = ALERT enabled. This applies only if Pin 8 is configured as ALERT, otherwise it has no effect. 6 Mon/STBY Setting this bit to 1 places the ADT7482 in standby mode (that is, it suspends all temperature measurements (ADC). The SMBus remains active and values can be written to and read from the registers. THERM and ALERT are also active in standby mode. Changes made to the limit registers in standby mode that effect the THERM or ALERT outputs cause these signals to be updated. Default = 0 = temperature monitoring enabled. 5 AL/TH This bit selects the function of Pin 8. Default = 0 = ALERT. Setting this bit to 1 configures Pin 8 as THERM2 pin. 4 Reserved Reserved for future use. 3 Remote 1 /Remote 2 Setting this bit to 1 enables Remote 2 values to be read from the Remote 1 registers. Default = 0 = Remote 1 temperature values and limits are read from these registers. 2 Temp Range Setting this bit to 1 enables the extended temperature measurement range (−50°C to +150°C). Default = 0 = (0°C to +127°C). 1 Mask R1 Setting this bit to 1 masks ALERTs due to the Remote 1 temperature exceeding a programmed limit. Default = 0. 0 Mask R2 Setting this bit to 1 masks ALERTs due to the Remote 2 temperature exceeding a programmed limit. Default = 0. Table 10. Configuration 2 Register (Read/Write Address = 0x24) Bit Mnemonic Description 7 Lock Bit Setting this bit to 1 locks all lockable registers to their current values. This prevents settings from being tampered with until the device is powered down. Default = 0. <6:0> Res Reserved for future use. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |