| поискавой системы для электроныых деталей |
|
FSFLK датащи(PDF) 26 Page - NXP Semiconductors |
|
|
|||||||||||||||||||||||||||||
FSFLK датащи(HTML) 26 Page - NXP Semiconductors |
|
26 / 37 page ![]() Mechanical and Electrical Specifications 26 Freescale Sensor Fusion Library for Kinetis MCUs, Rev. 0.7, 9/2015 Freescale Semiconductor, Inc. Table 14. Sensor/Configuration Imposed Limitations Characteristic Symbol Min Max Unit Maximum Angular Rate ARmax –2000 +2000 dps Linear Acceleration LAmax –4 +4 g Magnetic Field Bmax –1200 +1200 µ T It is believed that the fusion algorithms themselves have no upper limits on any of the parameters above. These are strictly limits associated with the specific physical sensors used to characterize the library. 4.8.5 9-Axis Parametrics Table 15 provides guidance for the 9-axis (accelerometer/magnetometer/gyro) indirect Kalman filter implementation. NOTE: All parametrics provided in the following table are based on build 4.17 simulations. Build 5.00 simulations are still pending. Table 15. 9-axis Sensor Fusion Performance Metrics Characteristic Symbol Conditions(s) Min Typ Max Unit Orientation static drift OSD See Orientation Static Drift — 0.05 — degrees Orientation static noise OSN See Orientation Static Noise — 1.21 — degrees RMS Orientation dynamic drift ODD See Orientation Dynamic Drift — 0.17 — degrees Max angular Rate ARMAX See Maximum Angular Rate — 1600 Error! Reference source not found. — dps Orientation response delay ORD See Orientation Response Delay — <1 — 2fusion time interval Gyro offset step response TGOSR See Gyro Offset Step Response — 3.76 — seconds Error in computed linear acceleration LAE See Error in Computed Linear Acceleration — 0.243 — g Compass heading linearity 3 CHl See Compass Heading Linearity and Accuracy — 1.02 — degrees Compass heading accuracy CHacc — 1.37 — degrees Orientation magnetic immunity - static device Omis See Orientation Magnetic Immunity (Static Device) — 9.36 — degrees Orientation magnetic immunity - moving device Omim See Orientation Magnetic Immunity (Moving Device) — 8.98 — degrees |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |