| поискавой системы для электроныых деталей |
|
MPC9993 датащи(PDF) 3 Page - Renesas Technology Corp |
|
|
|||||||||||||||||||||||||||||
MPC9993 датащи(HTML) 3 Page - Renesas Technology Corp |
|
3 / 12 page ![]() MPC9993 REVISION 3 JANUARY 23, 2013 3 ©2013 Integrated Device Technology, Inc. MPC9993 Data Sheet INTELLIGENT DYNAMIC CLOCK SWITCH (IDCS) PLL CLOCK DRIVER Table 2. Absolute Maximum Ratings(1) 1. Absolute maximum continuous ratings are those maximum values beyond which damage to the device may occur. Exposure to these conditions or conditions beyond those indicated may adversely affect device reliability. Functional operation at absolute-maximum-rated conditions is not implied. Symbol Characteristics Min Max Unit Condition VCC Supply Voltage –0.3 3.9 V VIN DC Input Voltage –0.3 VCC+0.3 V VOUT DC Output Voltage –0.3 VCC+0.3 V IIN DC Input Current 20 mA IOUT DC Output Current 50 mA TS Storage Temperature –65 125 C Table 3. General Specifications Symbol Characteristics Min Typ Max Unit Condition VTT Output termination voltage VCC – 2 V MM ESD Protection (Machine model) 175 V HBM ESD Protection (Human body model) 1500 V CDM ESD Protection (Charged device model 1000 V LU Latch-up Immunity 100 mA CIN Input Capacitance 4.0 pF Inputs JA Thermal Resistance Junction to Ambient JESD 51-3, single layer test board JESD 51-6, 2S2P multilayer test board 83.1 73.3 68.9 63.8 57.4 59.0 54.4 52.5 50.4 47.8 86.0 75.4 70.9 65.3 59.6 60.6 55.7 53.8 51.5 48.8 C/W C/W C/W C/W C/W C/W C/W C/W C/W C/W Natural convection 100 ft/min 200 ft/min 400 ft/min 800 ft/min Natural convection 100 ft/min 200 ft/min 400 ft/min 800 ft/min JC Thermal Resistance Junction to Case 23.0 26.3 C/W MIL-SPEC 883E Method 1012.1 TJ Operating Junction Temperature(1) (continuous operation) MTBF = 9.1 years 1. Operating junction temperature impacts device life time. Maximum continuous operating junction temperature should be selected according to the application life time requirements (See application note AN1545 for more information). The device AC and DC parameters are specified up to 110°C junction temperature allowing the MPC9993 to be used in applications requiring industrial temperature range. It is recommended that users of the MPC9993 employ thermal modeling analysis to assist in applying the junction temperature specifications to their particular application. 110 C |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |