| поискавой системы для электроныых деталей |
|
TMDS341APFCRG4 датащи(PDF) 21 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TMDS341APFCRG4 датащи(HTML) 21 Page - Texas Instruments |
|
21 / 25 page ![]() www.ti.com SDAn Switch Box TMDS341A SDA_Sink VDDsink Rupsink Csink Ccable2 CO CI Ccable1 Csource VDDsource Rupsource Source Sink Csource Sink TMDS341A SDA_Sink SDAn Source Ccable Csink DVI/HDMI RX VDDsource Rupsource VDDsink Rupsink TMDS341A SLLS702 – MAY 2006 APPLICATION INFORMATION (continued) Figure 38. DDC Link from Source to Sink With External Switch Box Rupsource = 1.5-kΩ pull-up to 5 V Rupsink = 47-kΩ pull-up to 5 V Rtotal = Rupsource // Rupsink = 1.45 kΩ Ctotal = Csource // Ccable1 // Ci // Co // Ccable2 // Csink For standard mode I2C, the frequency is at 100 kHz, and the transition time must be less than 1 µs. The total allowable capacitance, C total, is then 814-pF. Csource and Csink are limited by the HDMI specification to 50 pF. C i/o for the TMDS341A is 10 pF max. The total capacitance from DVI or HDMI cables, Ccable1 and Ccable2, should then be less than 704 pF. Typical capacitance is 200 pF for a 28-AWG 5-m HDMI cable and 300 pF for a 28-AWG 5-m DVI cable. The recommended total cable length is the length of cable 1, Lcable1, plus the length of cable 2, Lcable2. For a 28-AWG DVI cable, the total cable length is 11 m; and for a 28-AWG HDMI cable, the total cable length is 17 m. This calculation is applicable to VIH ≤ Vpass. Maximum Bus Lengths for DTV Applications Figure 39 shows the TMDS341A being used as a switch in a DTV and being placed on the same PCB board as the DVI/HDMI receiver. Unlike Figure 38, the output connector of the TMDS341A stand-alone switch and the input connector of the sink are removed, which results in a lower capacitance in the DDC link and eliminates the impedance discontinuity. However, the capacitance of the removed connectors is relatively small, relative to the total allowable capacitance. The results from the previous section Maximum Bus Lengths for Switch Applications can be reused if the pull-up resistors and capacitances have the same values. The recommended total cable length is the length from source to sink. Figure 39. DDC Link From Source to Sink Without External Switch Box 21 Submit Documentation Feedback |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |