53 / 96 page ![]() 5.4 Overload (VDS high voltage, Overload (OVL)) During low duty cycle PWM operation on a shorted load, the ON time is normally too short to allow power limitation or overtemperature detection, and the ADC output does not report the current flowing on the channel. In this situation, the detection of the overload condition is quite difficult. To overcome this, the voltage drop on the PowerMOS (VDS) is measured every time the channel is turned OFF. If VDS (voltage across PowerMOS output stage) exceeds the threshold defined by the parameter VDS_OVL, an overload condition is detected. The corresponding bit in the overload status register VDSFSR (address from 0x20h to 0x23h depending on the channel) of the OUTSRx register is set (see the VDS feedback status bit (VDSFSR) in the OUTSRx register). Consequently, the bit 4 in the Global Status Byte is set if it is not masked in the CONFIG register through the dedicated “VDSMASK” bit. The VDSFSR is a warning and the channel can be switched on again even if the VDSFSRx bit is set. The VDSFSRx bit remains unchanged until a read and clear command on VDSFSR is sent by the SPI or until the output is turned off the next time, when the VDS is evaluated again. In case of low duty cycle PWM operation (i.e. 3% typical at 200 Hz in Bulb mode), if the output channel is switched ON for a very short time, VDS might be greater than a threshold defined by the parameter VDS_OVL even if the output is not in overload state so that a false warning is issued. Figure 24. Diagnostics flowchart for digital overload detection GADG1004171611PS Channel Feedback register Detailed diagnosis in ON state Evaluate Power limitation Over Load Temperature Status Critical: OT/PL on signalled channel End No err. Error bit(s) set Over Load on signalled channel(s) Please refer to Section 4.3.1 Global status byte description, Section 5.8 CHFBSR: Channel Feedback Status bit in OUTSRx Register and Section 5.11 VDS Feedback Status Register “VDSFSR” in OUTSRx register. 5.5 Open-load ON-state detection The open- load ON-state is performed by reading the digital current sense. In case the output is on and the reported digital current sense value is below the requested threshold, the open-load condition can be reported. VN9D5D20F Overload (VDS high voltage, Overload (OVL)) DS12936 - Rev 6 page 53/96 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |