2 / 6 page ![]() www.tracopower.com Page 2 of 6 Industrial Power Supplies TCL Series 24 to 240 Watt Input Specifications Input voltage range 85–264 VAC/85–375 VDC TCL 240 model: 85–132/187–264 VAC autoselect (no DC input) Output derating – at operation between 85...93 VAC/85...130 VDC 15% for TCL 060 & TCL 120 20% for TCL 024-112 & TCL 024-124 & TCL 240 30% for TCL 024-105 Input frequency 47–63 Hz Harmonic limits EN 61000-3-2, Class A Input current at full load (typ.) (115 VAC / 230 VAC) TCL 024 models: 0.35 A / 0.2 A TCL 060 models: 1.2 A / 0.6 A TCL 120 models: 2.0 A / 1.0 A TCL 240 model: 3.3 A / 1.7 A Recommended circuit breaker TCL 240 model: 10 A (characteristic C or slow blow fuse) all other models: 5 A (characteristic C or slow blow fuse) Output Specifications Output voltage adjustable range 5.1 VDC model: 5.0 – 5.25 VDC (potentiometer on frontpanel) 12 VDC models: 12 – 15 VDC (12 - 16 VDC for TCL 024-112) 24 VDC models: 24 – 28 VDC 48 VDC models: 48 – 56 VDC Output regulation (10 to 90% load variation) 2.5 % (1 % for TCL 60-112) Ripple and noise (20MHz bandwidth) <50 mV pk-pk Electronic short circuit protection current limitation at 120 % typ. (constant current, automatic recovery TCL 24 models: foldback, automatic recovery) Parallel operation output current characteristic suitable for parallel operation of max. 5 units (not for TCL 240-124) Overvoltage protection, trigger point 5.1 VDC model: <6.5 VDC 12/24 VDC models: <40 VDC 48 VDC models: <60 VDC Hold-up time (115 VAC / 230 VAC) min. 15 ms / min. 125 ms TCL 240 model: min. 15 ms / min. 40 ms Power OK signal (TCL 60, 120 & 240 models only) trigger output signal point (reference to – Vout) 12 VDC models: >11V 11.0 V ±1.0 V / 60 mA max. 24 VDC models: >22V 22.0 V ±2.0 V / 30 mA max. 48 VDC models: >44V 44.0 V ±4.0 V / 15 mA max. General Specifications Temperature ranges – Operating –10°C to +70°C max. – Storage (non operating) –25°C to +85°C Temperature derating – at 187...264 VAC or 265...375 VDC operation 1.7 %/K above +50°C – at 93...132 VAC or 130...187 VDC operation 1.1 %/K above +40°C – at 85...130 VDC operation 1.3 %/K above +30°C Humidity (non condensing) 95 % rel. H max. Temperature coefficient 0.02 %/K Switching frequency 55 – 180 kHz depending on load (frequency modulation) Efficiency 88 % typ. Isolation voltage – I/O isolation voltage (60 s) 3000 VAC |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |