| поискавой системы для электроныых деталей |
|
R-DR/CLIP датащи(PDF) 4 Page - Recom International Power |
|
|
|||||||||||||||||||||||||||||
R-DR/CLIP датащи(HTML) 4 Page - Recom International Power |
|
4 / 10 page ![]() www.recom-power.com REV.: 0/2023 PA-4 AC/DC Converter Specifications (measured @ Ta= 25°C, nom. Vin, full load and after warm-up unless otherwise stated) RACM30-K/277 Series REGULATIONS Parameter Condition Value Output Accuracy single output ±2.0% typ. dual output ±3.0% typ. Line Regulation low line to high line 5Vout ±1.0% typ. others ±0.5% typ. Load Regulation (7) 10% to 100% load 5Vout ±3.0% typ. others ±1.0% typ. Cross Regulation dual output only ±10.0% typ. Transient Response 25% load step change 4.0% max. recovery time 500µs typ. PROTECTIONS Parameter Type Value Input Fuse (8) internal T3.15A, slow blow type Short Circuit Protection (SCP) hiccup, auto recovery Over Voltage Protection (OVP) 150% - 195%, hiccup mode Over Current Protection (OCP) <180%, hiccup mode Over Voltage Category (OVC) OVCIII 5000m DC OK LED only for “/PMP” green Class of Equipment Class II Isolation Voltage (9) I/P to O/P, I/P to Case, O/P to Case 1 minute 4kVAC Isolation Resistance VISO = 500VDC 1G Ω min. Isolation Capacitance I/P to O/P, 100kHz/0.1V 100pF max. Insulation Grade reinforced Leakage Current 100µA max. Notes: Note7: Operation below 10% load will not harm the converter, but specifications may not be met Notes: Note8: For system integration with DC operation, consider a suitable DC fuse in front of the input Note9: For repeat Hi-Pot testing, reduce the time and/or the test voltage ENVIRONMENTAL Parameter Condition Value Operating Temperature Range @ natural convection <0.1m/s refer to “Derating Graph” -40°C to +90°C Maximum Case Temperature +110°C max. Temperature Coefficient 0.02%/K Operating Altitude (10) 5000m Operating Humidity non-condensing 90% RH max. Polution Degree potted version PD3 Vibration according to MIL-STD-202G 10-500Hz, 2G 10min./1cycle, period 60min. each along x,y,z axes continued on next page Notes: Note10: Recognized by safety agency for safe operation up to 5000m. High altitude operation may impact the performance and lifetime. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |