поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

ISO808TR датащи(PDF) 20 Page - STMicroelectronics

номер детали ISO808TR
подробное описание детали  Galvanic isolated octal high-side power solid state relay for high inductive loads
PDF  38 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  STMICROELECTRONICS [STMicroelectronics]
домашняя страница  http://www.st.com
Logo STMICROELECTRONICS - STMicroelectronics

ISO808TR датащи(HTML) 20 Page - STMicroelectronics

Back Button ISO808TR Datasheet HTML 16Page - STMicroelectronics ISO808TR Datasheet HTML 17Page - STMicroelectronics ISO808TR Datasheet HTML 18Page - STMicroelectronics ISO808TR Datasheet HTML 19Page - STMicroelectronics ISO808TR Datasheet HTML 20Page - STMicroelectronics ISO808TR Datasheet HTML 21Page - STMicroelectronics ISO808TR Datasheet HTML 22Page - STMicroelectronics ISO808TR Datasheet HTML 23Page - STMicroelectronics ISO808TR Datasheet HTML 24Page - STMicroelectronics Next Button
Zoom Inzoom in Zoom Outzoom out
 20 / 38 page
background image
6.4
FAULT indication
The FAULT pin is an active low open drain output indicating fault conditions. This pin is activated when at least
one of the following conditions occurs:
•
Junction over-temperature (TJX >TJSD) of one or more channels of the Process Stage or case shut-down
protection (TC >TCSD) is active
•
Internal communication error.
The communication error is intended as an internal data corruption event in the data transfer through isolation. In
case of communication error, the outputs are initially kept in the previous status and then reset (turned off) at the
first communication error during data transfer of the refresh signal
6.4.1
Junction overtemperature
The thermal status of the device is updated during each transmission sequence between the two isolated stages.
In SCM operation, when LOAD signal is high and SYNC one is low, the communication between the two stages
is disabled. In this case the thermal status of the device cannot be updated, and the FAULT indication could be
different to the actual status. In any case, the thermal protections of the channel outputs in the Process Stage are
always operative.
Figure 15. Thermal status update
ISO808, ISO808-1
FAULT
indication
DS14169 - Rev 1
page 20/38



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com