MODEL NUMBERS
7PCV2415
7PCV2425
10PCV2415 10PCV2425 10PCV2450 10PCV2475 10PCV2490
OUTPUT SPECIFICATIONS➀
Operating Voltage (47-63 Hz) [Vrms]
100-240
100-240
100-240
100-240
100-240
Max. Load Current Range [Arms]
.15-15
.15-25
.15-50
.15-75
.15-90
Transient Overvoltage [Vpk]
600
600
600
600
600
Max. Surge Current, (1 Cycle) [Apk]
150
250
625
1000
1200
Max. Off-State Leakage Current @ Rated Voltage [mA]
10
15
20
20
20
Maximum I 2 t for Fusing (8.3 msec) [A 2sec]
94
260
1620
4150
6000
Maximum Voltage Drop (100% On) [Vpk]
1.6
1.6
1.6
1.6
1.6
Minimum Off-State dv/dt [V/µsec]
200
200
200
200
200
Power Factor (Min.) with Max. Load
0.5
0.5
0.5
0.5
0.5
INPUT SPECIFICATIONS ➀
7PCV24xx
10PCV24xx
Control Voltage Range
2-7 Vdc
2-10 Vdc
Typical Input Current @ 5 Vdc
4 mA
4 mA
GENERAL NOTES
➀ All parameters at 25º C unless otherwise specified.
• Operates at 60Hz & 50Hz
• Internal Snubber
• Industry Standard Package
• Control Circuit Requires No
Adjustment or Calibration
FastFax Document No. 204
SERIES PCV.
Rev. 041902
PAGE 1 OF 2
The PCV Series proportional controllers
are self contained power control mod-
ules integrating a complete phase fired
logic control system and a solid state
relay in the same standard package.
Typical applications include heaters,
vibratory feeders and tungsten lamps.
Series PCV
Analog Input Power Controller
TYPICAL APPLICATIONS
• Industrial Temperature Controllers
• Light Dimming
• Vibratory Feeders
• Resistive Heating Elements
• Conveyor Speed Control
UNSUITABLE APPLICATIONS
The PCV is not suitable for some load applications
including, but not limited to the following:
• AC Motor Control
• Three Phase Motors
• Transformers requiring pure sine wave input
• Zero Crossing Applications
Please contact Crydom’s application
engineering department for additional
information and specific application
questions.
100
80
60
40
20
0
2.5
4.5
5.5
3.5
6.5
7.5
8.5
9.5
Input Voltage
Percentage On vs. Input Voltage
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
60 Hz
© 2002 CRYDOM CORP, Specifications subject to change without notice.
For recommended applications and more information contact:
USA: Sales Support (877) 502-5500 Tech Support (877) 702-7700 FAX (619) 710-8540
Crydom Corp, 2320 Paseo de las Americas, Ste. 201, San Diego, CA 92154
Email: sales@crydom.com WEB SITE: http://www.crydom.com
UK: +44 (0)1202 365070 • FAX +44 (0)1202 365090 Crydom International Ltd., 7 Cobham
Road, Ferndown Industrial Estate, Ferndown, Dorset BH21 7PE, Email: intsales@crydom.com.
GERMANY: +49 (0)180 3000 506