| поискавой системы для электроныых деталей |
|
LLC6 датащи(PDF) 1 Page - Littelfuse |
|
|
|||||||||||||||||||||||||||||
LLC6 датащи(HTML) 1 Page - Littelfuse |
|
1 / 2 page ![]() © 2016 Littelfuse Protection Relays & Controls www.littelfuse.com/ Rev: 1-A-062716 Protection Relays Pump Controls and Liquid Level Controls www.littelfuse.com/llc6 LLC6 SERIES Description The LLC6 Series is a plug-in, single-probe conductive liquid level control designed for low liquid level cutoff protection. It offers a factory fixed time delay of 1 - 60s and is available in input voltages of 24, 120, or 230VAC. LED indicator illuminates whenever the LLC6’s 10A, SPDT output relay is energized. Available with automatic/manual reset or a special manual reset with power outage feature, which auto resets the unit when power is restored and the water level is acceptable. 24VAC and 120VAC units are recognized as limit switches under UL353 (230VAC units are UL508) and CSA certified under Standard 14. Operation Automatic Reset (Reset terminals not connected): When liquid rises to the low level cutoff probe, the output relay and the LED indicator energize. When the liquid falls below low level cutoff probe, the output relay and the LED indicator de-energize after a fixed time delay. Manual Reset (Reset switch connected): When the liquid level falls below the low level probe, the output relay and LED de-energize after a fixed time delay. When the liquid level rises to the low level probe, the output relay and LED indicator remain de-energized until the manual reset switch is opened; then they energize immediately. Power Outage Manual Reset (Reset switch connected): A power outage causes the output relay and LED indicator to de-energize. Upon restoration of power, if the liquid level is above the low level probe, the output relay and LED indicator will re-energize. If the liquid level is below the low level probe, the output relay and LED indicator remain de-energized until the Normally Closed (NC) reset switch is opened. Features & Benefits FEATURES BENEFITS Isolated 12VAC on probe Prevents electrolysis Industry standard 11-pin octal plug connection Eliminates need for special connectors LED indication Visual indication output relay is energized Power outage protection (see ordering table for models) Automatically resets the unit when power is restored and the water level is acceptable Wiring Diagram Low Level Cutoff Liquid Level Controls Ordering Information MODEL INPUT VOLTAGE TIME DELAY (FIXED) SENSE RESISTANCE RESET LLC6210F10M 24VAC 10s 10kΩ Manual/Automatic LLC6410F10M 120VAC 10s 10kΩ Manual/Automatic LLC643F26M 120VAC 3s 26kΩ Manual/Automatic LLC6610F5P 230VAC 10s 5kΩ Power Outage Manual Reset If you don’t find the part you need, call us for a custom product 800-843-8848 L1 N/L2 Metal Tank or use additional Probe PC = Probe Common P = Probe V = Voltage R = Optional NC Reset Switch Connect common to conductive tank. Additional probe is necessary for non-conductive or insulated tanks. 11-PIN |
Аналогичный номер детали - LLC6 |
|
Аналогичное описание - LLC6 |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |