24 / 121 page ![]() B7A/B7AS B7A/B7AS 22 Connection of Single Power Supply to Input or Output Terminal SIG SIG – (–) + (+) SIG SIG – (–) + (+) ERR ERROR – + SIG IN OUT Note: In this example, a shielded transmission cable with a thickness of 0.75 mm2 is used, through which a current of 1.8 A max. can be transmitted. It is recommended that the shield be grounded. The maximum transmission distance is 10 m if a VCTF wire with a thickness of 0.75 mm2 is used instead of a shielded cable for the transmission path. +– DC power supply (24 V) Transmission distance 50 m max. Shielded cable GND B7A/B7AS B7A/B7AS Modular Models I/O Delay: Normal Speed Connection of Single Power Supply to Input or Output Terminal Note: In this example, a VCTF transmission cable with a thickness of 0.75 mm2 min. is used, through which a current of 1.8 A max. can be transmitted. Note: A VCTF cable with a thickness of 0.75 mm2 min. must be used for signal transmission. Connection of Independent Power Supplies Input terminal Output terminal Transmission distance 500 m max. 12 to 24 VDC 13 14 15 16 17 18 19 20 21 22 23 24 13 14 15 16 17 18 19 20 21 22 23 24 12 11 10 9 8 7 6 5 4 3 2 1 12 11 10 9 8 7 6 5 4 3 2 1 12 to 24 VDC 13 14 15 16 17 18 19 20 21 22 23 24 12 11 10 9 8 7 6 5 4 3 2 1 Input terminal Output terminal Transmission distance 100 m max. 13 14 15 16 17 18 19 20 21 22 23 24 12 11 10 9 8 7 6 5 4 3 2 1 24 VDC I/O Delay: High Speed Connection of Single Power Supply to Input or Output Terminal Note: In this example, a shielded transmission cable with a thickness of 0.75 mm2 min. is used, through which a current of 1.8 A max. can be transmitted. It is recom- mended that the shield be grounded. The maximum transmission distance is 10 m if a VCTF wire with a thickness of 0.75 mm2 is used instead of a shielded cable for the transmission path. Note: A shielded cable with a thickness of 0.75 mm2 min. must be used for signal transmission. It is recom- mended that the shield be grounded. The maximum transmission distance is 10 m if a VCTF wire with a thickness of 0.75 mm2 is used instead of a shielded cable for the transmission path. Connection of Independent Power Supplies Input terminal Output terminal 12 to 24 VDC Transmission distance 100 m max. 13 14 15 16 17 18 19 20 21 22 23 24 12 11 10 9 8 7 6 5 4 3 2 1 13 14 15 16 17 18 19 20 21 22 23 24 12 11 10 9 8 7 6 5 4 3 2 1 12 to 24 VDC GND 13 14 15 16 17 18 19 20 21 22 23 24 12 11 10 9 8 7 6 5 4 3 2 1 Input terminal Output terminal 24 VDC 13 14 15 16 17 18 19 20 21 22 23 24 12 11 10 9 8 7 6 5 4 3 2 1 GND Transmission distance 50 m max. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |