136 / 151 page ![]() 6.4.3 Internal regulator for open load (OL) detection Each channel features an internal regulator with limited current capability that regulates the output node voltage Vout around VOUT_OL, which falls in the middle of the [VLVT; VOL] range. OL regulators are always ON, independently on the ENABLE_DIAGNOSTIC bit value. Table 46. Open Load output voltage Symbol Parameter Min. Typ. Max. Unit VOUT_OL Vout node voltage in case of open load 2.25 2.5 2.75 V Note: Vout corresponds to DRNx pin for LS NMOS and HS PMOS configurations, while it's SNGPx pin for HS NMOS configuration. Regulator current capability IDIAG can be programmed via diag_i_config_xx bit as follows: Table 47. Vout regulator current capability IDIAG diag_i_config_xx Min. Max. Unit 0 60 100 µA 1 0.6 1 mA A higher current capability allows compensating the leakage of external devices (FET, recirculation diodes, etc.) The current limitation feature allows distinguishing between OL and STB/STG faults: • In case of open load, the regulator is able to drive Vout around VOUT_OL and the OL fault is flagged; • In case of STB/STG fault, due to the limited current capability, the regulator has no effect on Vout. Therefore, output node voltage stays below VLVT (STG on LS) or above VOL (STB on HS). Refer to Figure 37 and Figure 39 for OL regulator operation in HS configuration. Refer to Figure 38 and Figure 39 for OL regulator operation in LS configuration. 6.4.4 Fast charge/discharge currents In order to reliably detect a fault, the Vout voltage must be stable before the settling time tDIAG expires. In case of STB/STG faults, high current capability of battery and ground supplies guarantee fast Vout settling. In case of open load, Vout must be brought in the [VLVT; VOL] range before tDIAG expires in order to guarantee fault detection. L9945 implements internal fast charge/discharge currents in order to allow settling of Vout in a time suitable for detection: • When HS transistor is switched OFF, a fast discharge current IFAST_DIS rapidly decreases Vout down to VOL to help the OL regulator detect an eventual open load fault (see Figure 37 and Figure 39). IFAST_DIS is enabled in case: – The HS channel has been just switched OFF; – The settling time tDIAG is still running; – Vout is above VOL. • When LS transistor is switched OFF, a fast charge current IFAST_CHG rapidly increases Vout up to VLVT to help the OL regulator detect an eventual open load fault (see Figure 38 and Figure 39). IFAST_CHG is enabled in case: – The LS channel has been just switched OFF; – The settling time tDIAG is still running; – Vout is below VLVT. L9945 OFF state diagnostics DS12275 - Rev 8 page 136/151 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |