20 / 61 page ![]() Functional description L99LD20 20/61 DS11366 Rev 3 3.3.2 Overtemperature shutdown If the junction temperature of one of the buck mosfets rises above the shutdown temperature TTSD, an overtemperature event (OVT) is detected. The channel is switched off and the corresponding bit (OVT1 or OVT2) is set in the status register SR#1<5> for Buck1 and SR#2<23> for Buck2. Overtemperature events are also reported in the Global Status Byte register and in particular bit 27 FE1 is set. In normal mode the corresponding buck converter is latched off, until the following conditions are fulfilled: 1. TJX drops below the thermal shutdown reset threshold TTSD-TTSD_HYS. 2. Subsequently the microcontroller sends a read and clear command, in order to reset OVT1 or OVT2 bit located in the Status register SR#1<5> or SR#2<23>. In fail safe mode (Limp Home), the device applies an auto restart of the fault buck converter with a period equal to tAUTORESTART, provided that the TJX falls below TSD reset threshold (TTSD-TTSD_HYS). 3.3.3 VS under voltage lockout If the VS supply falls below VS_UV (VS under voltage threshold), the buck converters will be deactivated, regardless of the SPI control registers or DIN. This feature is implemented, in order to avoid any operation outside the allowed VS operating range. 3.3.4 Buck TON minimum operation Buck minimum on time operation is detected when the corresponding failure counter counts N_Ton_min_fail switching cycles (also nonconsecutive), during which ILx_PEAK is reached between TBLANK_BUCK and TON_MIN_BUCK. In normal mode (Active mode), once minimum TON operation is validated, flag TON_MIN_OPx is set and the corresponding Buckx converter is latched off, until the microcontroller sends a frame and clears the corresponding status bit (SR#1<2> and SR#1<1>). In fail safe mode (Limp Home), once a minimum TON violation is validated, the corresponding buck converter is latched off until automatically cleared by an auto-restart procedure, with a period equal to tAUTORESTART. The failure counter is not incremented during the startup phase (TSTARTUP). The failure counter is reset if Nton_min_fail_reset consecutive pulses are detected with TON longer than TON_MIN_BUCK. 3.3.5 Buck output’s short circuit to GND A shorted buck output to GND is detected when LED string voltage (VLED) is lower than a specified threshold (VLED_SHT) and the corresponding failure counter counts Nton_min_fail switching cycles (also nonconsecutive), during which ILx_PEAK is reached between TBLANK_BUCK and TON_MIN_BUCK. In normal mode (Active mode), once a short circuit is validated, flag SHTx is set and the corresponding Buckx converter is latched off, until the microcontroller sends a frame and clears the corresponding status bit (SR#1<7> and SR#1<6>). |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |