| поискавой системы для электроныых деталей |
|
EMC1043 датащи(PDF) 21 Page - SMSC Corporation |
|
|
|||||||||||||||||||||||||||||
EMC1043 датащи(HTML) 21 Page - SMSC Corporation |
|
21 / 28 page ![]() 1°C Triple Temperature Sensor with Beta Compensation and Hotter of Two Zones Datasheet SMSC EMC1043 21 Revision 1.37 (09-05-06) DATASHEET 4.5 Configuration 2 Register - (04h) The Configuration 2 Register controls the basic functionality of the EMC1043 that is NOT compatible with the EMC1023. Bit 3 - MAX_RES - controls the external diode conversion time during dynamic averaging. Although the dynamic averaging may be used to increase the ADC resolution, only 11 bits of data are available in the temperature registers. ‘0’ - the dynamic averaging will set the ADC averaging factor at 1x when the conversion rate is set at 16 conversions per second and 2x at conversion rates lower than 16 per second. ‘1’ (default) - the dynamic averaging will set the ADC averaging factor at 1x when the conversion rate is set at 16 conversions per second, 2x at 8 conversions / second and 4x at conversion rates lower than 8 per second. Bit 2 - DA_n - controls the dynamic digital averaging circuitry. See Section 3.3.2. ‘0’ (default) - dynamic averaging is enabled. Depending on the selected conversion rate, the ADC averaging factor is increased for the external diodes. ‘1’ - dynamic averaging is disabled. The ADC averaging factor will remain fixed at 1x for all conversion rates and will allow increased power savings at the slower conversion rates. Bit 1 - COMP - configures the device to perform a comparison for the Hotter of Two mode (see Section 3.3, "Operation During Run Mode," on page 12.) ‘0’ (default) - the device is in normal mode ‘1’ - the device is in Hotter of Two mode. In this mode, the two external diode channels are measured and compared against each other. The hotter of the two channels has its data loaded into the External Diode 2 Data Registers. The Internal Diode and External Diode 1 Data Registers remain unaffected. Bit 0 - REC - controls the Resistance Error Correction circuitry '0' - - The Resistance Error Correction circuitry is disabled. '1' (default) - The Resistance Error Correction circuitry is active and will automatically correct for up to 100 ohms of series resistance in the diode lines for both External Diode 1 and External Diode 2 channels. 4.6 One Shot Register - (0Fh) The One Shot Register is an address place holder for the one-shot command. Writing to the address initiates the command. The data written is not important and is not stored. Reading from the one-shot registers will always return 00h. Table 4.5 Configuration 2 Register ADDR REGISTER B7B6B5B4 B3 B2 B1 B0 DEFAULT 04h CFG2 - - - - MAX_RES DA_n COMP REC 09h Table 4.6 One Shot Registers ADDR REGISTER B7 B6 B5 B4 B3 B2 B1 B0 DEFAULT 0Fh One Shot Conversion Writing to this register address initiates the one-shot. The data is not important and is not stored 00h |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |