| поискавой системы для электроныых деталей |
|
CC2430-RTR1-F32 датащи(PDF) 101 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
CC2430-RTR1-F32 датащи(HTML) 101 Page - Texas Instruments |
|
101 / 234 page ![]() CC2430 CC2430 PRELIMINARY Data Sheet (rev. 1.03) SWRS036A Page 101 of 232 and T1CTL.CH2IF for channel 2. An interrupt request is generated if the corresponding interrupt mask bit on T1CCTL0.IM, T1CCTL1.IM, or T1CCTL2.IM, respectively, is set. Examples of output compare modes in various timer modes are given in the following figures. Edge-aligned PWM output signals can be generated using the timer modulo mode and channels 1 and 2 in output compare mode 6 or 7 as shown in Figure 23. The period of the PWM signal is determined by the setting T1CC0 and the duty cycle for the channel output is determined by T1CCn. The timer free- running mode may also be used. In this case CLKCON.TICKSPD and the prescaler divider value T1CTL.DIV set the period of the PWM signal. The polarity of the PWM signal is determined by whether output compare mode 6 or 7 is used. PWM output signals can also be generated using output compare modes 4 and 5 as shown in the same figure, or by using modulo mode as shown in Figure 24. Using output compare mode 4 and 5 is preferred for simple PWM. Centre-aligned PWM outputs can be generated when the timer up/down mode is selected. The channel output compare mode 4 or 5 is selected depending on required polarity of the PWM signal. The period of the PWM signal is determined by T1CC0 and the duty cycle for the channel output is determined by T1CCn. The centre-aligned PWM mode is required by certain types of motor drive applications and typically less noise is produced than the edge- aligned PWM mode because the I/O pin transitions are not lined up on the same clock edge. In some types of applications, a defined delay or dead time is required between outputs. Typically this is required for outputs driving an H-bridge configuration to avoid uncontrolled cross-conduction in one side of the H-bridge. The delay or dead-time can be obtained in the PWM outputs by using T1CCn as shown in the following: Assuming that channel 1 and channel 2 are used to drive the outputs using timer up/down mode and the channels use output compare modes 4 and 5 respectively, then the timer period (in Timer 1 clock periods) is: TP = T1CC0 x 2 and the dead time, i.e. the time when both outputs are low, (in Timer 1 clock periods) is given by: TD = T1CC1 – T1CC2 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |