21 / 105 page ![]() 20 Type Rated current In (A) Rated insulation voltage Ui (V) AC Standard 690V 500V 440V 400V 230V Frame (A) AC Breaking capacity (kA rms) IEC60947-2 Icu/Ics Number of poles Automatic tripping device 100 15, 20, 30, 40, 50, 60, 75, 100 690 10/5 200/200 200/200 200/200 200/200 234 Thermal, magnetic Fixed ampere rating and instantaneous 30 ~ 50, 60 ~ 100 690 – 15/8 25/13 30/15 50/25 34 NF100-UP NF100-SEP Electronic trip relay Adjustable ampere rating Adjustable long time delay operating time, short time delay pick up, and instantaneous Short time delay pick up current Variation is within ±15% of setting current 2 to 10 Ir 30 60-75-90-105-120-150- 180-210-240-300 40 80-100-120-140-160- 200-240-280-320-400 50 100-125-150-175-200- 250-300-350-400-500 60 120-150-180-210-240- 300-360-420-480-600 75 150-187.5-225-262.5-300- 375-450-525-600-750 100 200-250-300-350-400- 500-600-700-800-1000 Instantaneous pick up current Variation is within ±15% of setting current 4 In ~ 16 In 30 ~ 50 200 ~ 800 60 ~ 100 400 ~ 1600 Rating (A) and Inst. (A) 15 225 ± 45 20 300 ± 60 30 450 ± 90 40 600 ± 120 50 750 ± 150 60 900 ± 180 75 1125 ± 225 100 1500 ± 300 Low-inst Number of poles Automatic tripping device Rating (A) and Inst. (A) – – Generator Automatic tripping device Rating (A) and Inst. (A) Number of poles – – Mag-Only Number of poles Automatic tripping device Rating (A) and Inst. (A) – – – – – – – 3 – – – – NF100-HEP 30 ~ 50, 60 ~ 100 690 5/3 30/15 50/25 50/25 100/50 34 Electronic trip relay Adjustable ampere rating Adjustable long time delay operating time, short time delay pick up, and instantaneous Short time delay pick up current Variation is within ±15% of setting current 2 to 10 Ir 30 60-75-90-105-120-150- 180-210-240-300 40 80-100-120-140-160- 200-240-280-320-400 50 100-125-150-175-200- 250-300-350-400-500 60 120-150-180-210-240- 300-360-420-480-600 75 150-187.5-225-262.5-300- 375-450-525-600-750 100 200-250-300-350-400- 500-600-700-800-1000 Instantaneous pick up current Variation is within ±15% of setting current 4 In ~ 16 In 30 ~ 50 200 ~ 800 60 ~ 100 400 ~ 1600 – – 3 – – – – Electronic trip relay Adjustable ampere rating Adjustable long time delay operating time, short time delay pick up, and instantaneous Electronic trip relay Adjustable ampere rating Adjustable long time delay operating time, short time delay pick up, and instantaneous Rating : 30 ~ 50A, 60 ~ 100A Inst. : Operating characteristics must be adjusted as follows. STD ≤ 3 (Is setting) LTD : minimum setting (TL = 12sec setting) Rating : 30 ~ 50A, 60 ~ 100A Inst. : Operating characteristics must be adjusted as follows. STD ≤ 3 (Is setting) LTD : minimum setting (TL = 12sec setting) |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |