2 / 7 page ![]() G3PC 2 Specifications ■ Ratings (at an Ambient Temperature of 25°C) Detection Power Supply Operating Circuit Main Circuit Alarm Output ■ Characteristics Engineering Data Rated power supply voltage 100 to 240 VAC (50/60 Hz) Operating voltage range 75 to 264 VAC (50/60 Hz) Current consumption 15 mA AC max. (at 200 VAC) Input method Voltage input Rated input voltage 12 to 24 VDC Operating input voltage range 9.6 to 30 VDC Must operate voltage 9.6 VDC max. Must release voltage 1 VDC min. Input current 7 mA DC max. (at rated input voltage) Rated load voltage 100 to 240 VAC (50/60 Hz) Operating voltage range 75 to 264 VDC (50/60 Hz) Applicable load current 20 A (Ta = 40) Minimum load current 0.1 A Inrush current resistance (peak value) 220 A (60 Hz, 1 cycle) Permissible (I2t) 260 A2s Applicable load (with Class-1 AC resistive load) 4 kW (at 200 VAC) Output OFF collector voltage 30 VDC max. Maximum carry current 0.1 A Output form Independent NPN open collector Operate time 1/2 of load power source cycle + 1 ms max. Release time 1/2 of load power source cycle + 1 ms max. Main circuit Output ON voltage drop 1.6 V rms max. OFF leakage current 10 mA max. (at 200 VAC) Alarm output Output ON voltage drop 1.5 V max. OFF leakage current 0.1 mA max. Insulation resistance 100 M Ω min. (at 500 VDC) Dielectric strength 2,500 VAC, 50/60 Hz for 1 min Vibration resistance Destruction: 10 to 55 to10 Hz, 0.35-mm single amplitude Shock resistance Destruction: 294 m/s2 Ambient temperature Operating: −20 to 60°C (with no icing or condensation) Storage: −30 to 70°C (with no icing or condensation) Ambient humidity 45% to 85% Weight Approx. 300 g Certified standards UL508, CSA22.2 No. 14, EN60947-4-3 (IEC947-4-3); Certified by VDE EMC Emission: EN55011 Group 1 Class B Immunity: EN61000-6-2 250 200 150 100 50 0 10 30 50 100 300 500 1,000 3,000 5,000 Energized time (ms) 0 2 4 6 8 10 25 20 15 10 5 0 10 20 30 40 -20 020 40 60 80 100 The figure will be less than 1/2 the rated value for repetitive input. One Cycle Surge Current: Non-repetitive Load Current vs. Ambient Temperature Input Voltage vs. Input Current Input Voltage vs. Input Impedance Ta = +25 °C Input impedance Input current Ambient temperature (°C) Input voltage (V) |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |