| поискавой системы для электроныых деталей |
|
LP3941A датащи(PDF) 27 Page - National Semiconductor (TI) |
|
|
|
|||||||||||||||||||||||||||||
LP3941A датащи(HTML) 27 Page - National Semiconductor (TI) |
|
27 / 32 page ![]() Flowchart Operation (Continued) passed. If LDO1 reaches 93%, the state machine advances to the RESET OFF DELAY state. If 60 ms have passed before the 93% level is achieved, the state machine returns to the STANDBY state and waits for another wakeup source. The RESET OFF DELAY state counts off 40 ms. If the battery voltage drops below the UVLO threshold of 2.5V, the state machine goes to the ENABLE RESET state and power down sequence. If LDO1 output drops below 85% of the nominal voltage the state machine returns to the TURNON LDOs state in an attempt to restart the LDO. If neither of these conditions occurs the state machine advances to the PS_HOLD DETECT state. In the PS_HOLD DETECT, RESET is deasserted and the state machine waits 35 ms for the PS_HOLD signal to go high. If PS_HOLD goes high within 35 ms of RESET going low the state machine advances to the IDLE state. If PS_HOLD in still low after 35 ms the state machine goes to ENABLE RESET state and the power down sequence. If battery voltage pins drops below the UVLO threshold, the state machine advances to the ENABLE RESET state and the power down sequence. If LDO1 output drops below its 85% point the state machine returns to the TURNON LDOs state in an attempt to try restart the LDOs. The state machine remains in the IDLE state until PS_HOLD goes low for 35 ms. If PS_HOLD is low for less than 35 ms the state machine remains in the IDLE state. If PS_HOLD stays low for more than 35 ms, the state machine advances to the ENABLE RESET state and the power down sequence. If LDO1 output falls below its 85% point the state machine returns to the TURNON LDOs state in an attempt to restart the LDOs. The UVLO is disabled in the IDLE state. The back-up battery charger is on. In the ENABLE RESET state RESET is asserted. After 60 ms all LDOs are turned off. UVLO as well as the back-up battery charger are on. Once LDO1 falls to its 85% point the state machine returns to the STANDBY state. The RTC_LDO is powered by the back-up battery and is always on (unless specifically disabled via the I 2C interface). www.national.com 27 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |