4 / 16 page ![]() DS1621 Table 2. TEMPERATURE/DATA RELATIONSHIPS TEMPERATURE DIGITAL OUTPUT (Binary) DIGITAL OUTPUT (Hex) +125°C 01111101 00000000 7D00h +25°C 00011001 00000000 1900h +½°C 00000000 10000000 0080h +0°C 00000000 00000000 0000h -½°C 11111111 10000000 FF80h -25°C 11100111 00000000 E700h -55°C 11001001 00000000 C900h Since data is transmitted over the 2-wire bus MSB first, temperature data may be written to/read from the DS1621 as either a single byte (with temperature resolution of 1°C) or as two bytes. The second byte would contain the value of the least significant (0.5°C) bit of the temperature reading as shown in Table 1. Note that the remaining 7 bits of this byte are set to all "0"s. Temperature is represented in the DS1621 in terms of a ½°C LSB, yielding the following 9-bit format: Figure 2. TEMPERATURE, TH, and TL FORMAT T = -25°C Higher resolutions may be obtained by reading the temperature and truncating the 0.5°C bit (the LSB) from the read value. This value is TEMP_READ. A Read Counter command should be issued to yield the COUNT_REMAIN value. The Read Slope command should then be issued to obtain the COUNT_PER_C value. The higher resolution temperature may be then be calculated by the user using the following: TEMPERATURE=TEMP_READ-0.25 + C PER COUNT REMAIN COUNT C PER COUNT _ _ ) _ _ _ ( − The DS1621 always powers up in a low power idle state, and the Start Convert T command must be used to initiate conversions. The DS1621 can be programmed to perform continuous consecutive conversions (continuous-conversion mode) or to perform single conversions on command (one-shot mode). The conversion mode is programmed through the 1SHOT bit in the configuration register as explained in the Operation and Control section of this datasheet. In continuous conversion mode, the DS1621 begins continuous conversions after a Start Convert T command is issued. Consecutive conversions continue to be performed until a Stop Convert T command is issued, at which time the device goes into a low-power idle state. Continuous conversions can be restarted at any time using the Start Convert T command. 1 1 1 0 0 1 1 1 0 0 0 0 0 0 0 0 MSB LSB 4 of 16 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |