2 / 8 page ![]() www.sensirion.com Version 1.0 – D1 – May 2020 2/8 1 Sensor Specifications1 CO2 Sensor Specifications Parameter Conditions Value CO2 measurement range I2C, UART PWM 0 – 40’000 ppm 0 – 5’000 ppm Accuracy2 400 ppm – 10’000 ppm ± (30 ppm + 3%MV) Repeatability3 400 ppm – 10’000 ppm ± 10 ppm Temperature stability4 T = 0 … 50°C ± 2.5 ppm / °C Response time5 τ 63% 20 s Accuracy drift over lifetime6 400 ppm – 10’000 ppm ASC field-calibration algorithm activated and SCD30 in environment allowing for ASC, or FRC field-calibration algorithm applied. ± 50 ppm Table 1: SCD30 CO2 sensor specifications Humidity Sensor Specifications7 Parameter Conditions Value Humidity measurement range - 0 %RH – 100 %RH Accuracy8 25°C, 0 – 100 %RH ± 3 %RH Repeatability3 - ± 0.1 %RH Response time5 τ 63% 8 s Accuracy drift - < 0.25 %RH / year Table 2: SCD30 humidity sensor specifications Temperature Sensor Specifications7 Parameter Conditions Value Temperature measurement range9 - - 40°C – 70°C Accuracy8 0 – 50°C ± (0.4°C + 0.023 × (T [°C] – 25°C)) Repeatability3 - ± 0.1°C Response time5 τ 63% > 10 s Accuracy drift - < 0.03 °C / year Table 3: SCD30 temperature sensor specifications 1 Default conditions of T = 25°C, humidity = 50 %RH, p = 1013 mbar, VDD = 3.3 V, continuous measurement mode with measurement rate = 2 s apply to values listed in the tables, unless otherwise stated. 2 Deviation to a high-precision reference in the calibrated range (400 – 10’000 ppm) of the SCD30. Accuracy is fulfilled by > 90% of the sensors after calibration. Rough handling, shipping and soldering reduces the accuracy of the sensor. Full accuracy is restored with FRC or ASC recalibration features. Accuracy is based on tests with gas mixtures having a tolerance of ± 1.5%. 3 RMS error of consecutive measurements at constant conditions. Repeatability is fulfilled by > 90% of the sensors. 4 Average slope of CO2 accuracy when changing temperature, valid at 400 ppm. Fulfilled by > 90% of the sensors after calibration. 5 Time for achieving 63% of a respective step function. Response time depends on design-in, heat exchange and environment of the sensor in the final application. 6 CO2 concentrations < 400 ppm may result in sensor drifts when ASC is activated. For proper function of ASC field-calibration algorithm SCD30 has to be exposed to air with CO2 concentration 400 ppm regularly. 7 Design-in of the SCD30 in final application and the environment impacts the accuracy of the RH/T sensor. Heat sources have to be considered for optimal performance. Please use integrated on-board RH/T compensation algorithm to account for the actual design-in. 8 Deviation to a high-precision reference. Accuracy is fulfilled by > 90% of the sensors after calibration. 9 RH/T sensor component is capable of measuring up to T = 120°C. Measuring at T > 70°C might result in permanent damage of the sensor. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |