Back Button Z84C9012VSC Datasheet HTML 23Page - Zilog, Inc. Z84C9012VSC Datasheet HTML 24Page - Zilog, Inc. Z84C9012VSC Datasheet HTML 25Page - Zilog, Inc. Z84C9012VSC Datasheet HTML 26Page - Zilog, Inc. Z84C9012VSC Datasheet HTML 27Page - Zilog, Inc. Z84C9012VSC Datasheet HTML 28Page - Zilog, Inc. Z84C9012VSC Datasheet HTML 29Page - Zilog, Inc. Z84C9012VSC Datasheet HTML 30Page - Zilog, Inc. Z84C9012VSC Datasheet HTML 31Page - Zilog, Inc.  
Zoom Inzoom in Zoom Outzoom out
 30 / 31 page
background image
Z84C90
KIO Serial/Parallel Counter Timer
PS011802-0902
25
Precautions & Limitations
The following describe the limitations of Revision A of the Z84C90 KIO.
Problem:
Daisy-chain. If the KIO has an Interrupt Pending during and Interrupt Acknowledge
cycle, KIO misses the status of the IE1 pin. This produces vector contention if there is a
higher interrupting device. It works fine if only one device is in the system.
Work Around:
There is no problem if the application has only one peripheral in the daisy chain. For two
or more peripherals in the system, a “hardware workaround circuit” is needed. Please con-
tact your local Zilog representatives to get more detailed information.
Problem:
Reset. KIO requires the M1 signal to exit from Reset state. If the M1 signal is not
received, the KIO can not be programmed. This is not a problem for users of the Z80
CPU.
Workaround:
If the CPU is other than a Z80, an M1 signal is needed to exit RESET status. Otherwise,
the KIO can not be programmed.
Problem:
Port C. When Port C is used as Parallel I/O (not as SIO’s modem signals) and there is a
status change on PC1 or PC6, the status of SYNCA or SYNCB (SIO cell) also changes.
Work Around:
Before using Port C as a parallel port, set the SIO modem signal mode back to Port C. This
procedure avoids the problem.
Problem:
Interrupt Acknowledge cycle. The KIO modifies the contents of the KIO control register
(specifically, the KIO modifies the daisy-chain configuration) if the CE pin is active dur-
ing the Interrupt Acknowledge cycle (with other conditions satisfied).



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com