5 / 6 page ![]() 5 EVDP610 outputs are not enabled or turned off. 3.1.9 Error Messages If for some reason, the communication or instruction did not take place an error message will appear in the text box on the top of the GUI, or an error message panel will tell the user the proper actions to take. It is always a good idea to update the GUI after an error has occurred to prevent the board from differing from the GUI in any way. This maybe accomplished by hitting either the READ IXDP610 STATUS button or by hitting the RESET button (the current settings will be lost if RESET is used). Hit the close button on any error panels to close the panel. 4.0 SERIAL OPERATION 4.1 RS-232 Serial Operation This remote control port allows a user to connect a personal computer as the remote host to the IXDP610. Utilizing a standard three wire interface and DEI’s defined communication protocol the user can write a custom control program for their particular testing needs. 4.1.1 Serial Data Packets The data packets sent to the IXDP610 over the serial bus should be of the following format: To Address From Address Op Code Data Stop Byte Where the data is as follows: Data Byte Function Value To Address IXDP610 Address 0x02h From Address Remote Host Address Variable [0 to255] Recommend 0x00h Operation Code The command hardware code See Instruction Set Data1 Any data to send to IXDP610 See Instruction Set Stop Byte Serial termination byte 0x0Ah The data packets returned by the DEI IXDP610 will be of the following format: To Address From Address Op Code Data Error Code Stop Byte Where the data is as follows: Data Byte Function Value To Address Remote Host Address Variable [0 to255] Recommend 0x00h From Address IXDP610 Address 0x02 Operation Code The command hardware code See Instruction Set Data Any data sent from the IXDP610 One unsigned byte Error Code Error is any non-zero byte, No Error = 0 See Error Code table Stop Byte Serial termination byte 0x0Ah 4.1.2 Common Instruction Set & Serial Data Packet Format: Instruction Opcode (hex) Form at (num ber of bytes=> all unsigned chars) Get Version1 0x05 Send-5, Receive-6 Get Version2 0x06 Send-5, Receive-6 Set Dead Tim e 0x10 Send-5, Receive-6 Set Pulse W idth 0x20 Send-5, Receive-6 Set Resolution 0x30 Send-5, Receive-6 Enable Outputs 0x40 Send-5, Receive-6 Reset 0x50 Send-5, Receive-6 Set Clock Divide 0x60 Send-5, Receive-6 Set Lockout 0x70 Send-5, Receive-6 Set Clock Select 0x80 Send-5, Receive-6 Read Pulse W idth 0x90 Send-5, Receive-6 Read Resolution 0x93 Send-5, Receive-6 Read Lock Status 0x94 Send-5, Receive-6 Read Clock Divide 0x95 Send-5, Receive-6 Read Output Enable Status 0x96 Send-5, Receive-6 4.1.3 Common Error Codes Error Code Description Problem Action 0x00 No Error N/A Command was successful, no errors. 0xE0 General Internal Error Timing Error on evaluation board None Recommended – reset board. If error is repeatable contact factory. 0xE1 Invalid Opcode Command Packet Incorrect or Corrupted Verify packet data integrity with emphasis on op-code byte. 0xE2 Control Latch locked Can’t write to control latch Unlock control latch or reset board. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |