| поискавой системы для электроныых деталей |
|
MAX11068 датащи(PDF) 21 Page - Maxim Integrated Products |
|
|
|||||||||||||||||||||||||||||
MAX11068 датащи(HTML) 21 Page - Maxim Integrated Products |
|
21 / 82 page ![]() 12-Channel, High-Voltage Sensor, Smart Data-Acquisition Interface For every module in the battery pack, a 1Fs communi- cation delay is incurred while the scan command is for- warded up the SMBus ladder. Therefore, the difference in the scan completion time from the first module to the last module in a chain is no more than 1Fs x (no. of mod- ules in the chain - 1) as shown in Figure 11. Taking the module conversion time and combining it with the communication delay, the overall sampling window of the system can be calculated: Sampling window = 11.3Fs + (5.67Fs + (no. of cells enabled per module -1) x 3.83Fs) x 2 phases + ((no. of modules per pack - 1) x 1Fs per module) So, for a battery pack that uses 12 cells per module and a system with four modules (total cell count = 48), the sampling window would be: Sampling Window = 11.3 + (5.67 + 11 x 3.83Fs) x 2 + ((4 Modules -1) x 1Fs) Sampling Window = (106.9Fs) + (3Fs) = 109.9Fs Thus, from the time the first device receives the scan command until the last device completes its measure- ment conversion, 109.9Fs elapse. The final aspect of the measurement conversion is the retrieval of data from all devices. A READALL command is the only way to transfer data from each device. Since up to 12 cells are measured, the READALL command must be performed for each cell whose data must be transferred. For each READALL command, there are 5 total bytes of overhead. These include the broadcast address byte, the command code byte (register address to be read), the I2C address byte, the data check byte, and the packet-error check (PEC) byte. Each of these bytes has an acknowledge bit associated with it. The register data from each device consists of 2 more bytes plus 2 acknowledge bits. Finally, the overall data stream consists of 3 more bits, start, stop, and repeated start. Thus, for a read of a single register from all modules, the total bit count is: READALL bit count = 3 + 5 x 8 + 5 + no. of modules x (2 x 8 + 2) = 120 Figure 11. Measurement Scan Timing for a Multimodule System SCAN AT t0 COMMAND FORWARDING DELAY = 1µs MODULE N tALL MODULES = (NO. OF MODULES X 1µs) + 107µs MODULE 5 tALL MODULES MODULE 1 MODULE 2 MODULE 3 MODULE 4 MAX11068 Maxim Integrated 21 |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |