21 / 44 page ![]() SLDN-03D1Ax 21 Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2019 Bel Power Solutions & Protection Rev. D1.04.19 The user must know which I2C addresses are reserved in a system for special functions and set the address of the module to avoid interfering with other system operations. Both 100kHz and 400kHz bus speeds are supported by the module. Connection for the Power Management Bus interface should follow the High Power DC specifications given in section 3.1.3 in the SMBus specification V2.0 for the 400kHz bus speed or the Low Power DC specifications in section 3.1.2. The complete SMBus specification is available from the SMBus web site, smbus.org. ADDR0 SIG_GND RADDR0 RADDR1 ADDR1 Figure 48. Circuit showing connection of resistors used to set the Power Management Bus address of the module. The SLDN-03D1Ax module can also be turned on and off via the Power Management Bus interface. The OPERATION command is used to actually turn the module on and off via the Power Management Bus, while the ON_OFF_CONFIG command configures the combination of analog ON/OFF pin input and Power Management Bus commands needed to turn the module on and off. Bit [7] in the OPERATION command data byte enables the module, with the following functions: 0 : Output is disabled 1 : Output is enabled This module uses the lower five bits of the ON_OFF_CONFIG data byte to set various ON/OFF options as follows: Bit Position 4 3 2 1 0 Access r/w r/w r/w r/w r Function PU CMD CPR POL CPA Default Value 1 0 1 1 1 PU: Sets the default to either operate any time input power is present or for the ON/OFF to be controlled by the analog ON/OFF input and the Power Management Bus OPERATION command. This bit is used together with the CP, CMD and ON bits to determine startup. Bit Value Action 0 Module powers up any time power is present regardless of state of the analog ON/OFF pin 1 Module does not power up until commanded by the analog ON/OFF pin and the OPERATION command as programmed in bits [2:0] of the ON_OFF_CONFIG register. CMD: The CMD bit controls how the device responds to the OPERATION command. Bit Value Action 0 Module ignores the ON bit in the OPERATION command 1 Module responds to the ON bit in the OPERATION command CPR: Sets the response of the analog ON/OFF pin. This bit is used together with the CMD, PU and ON bits to determine startup. Bit Value Action 0 Module ignores the analog ON/OFF pin, i.e. ON/OFF is only controlled through the Power Management Bus via the OPERATION command 1 Module requires the analog ON/OFF pin to be asserted to start the unit |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |