| поискавой системы для электроныых деталей |
|
CAD32FD датащи(PDF) 2 Page - Schneider Electric |
|
|
|||||||||||||||||||||||||||||
CAD32FD датащи(HTML) 2 Page - Schneider Electric |
|
2 / 3 page ![]() Plate Connections - terminals screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible without cable end screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)flexible without cable end screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)flexible with cable end screw clamp terminals 2 0.00…0.00 in² (1…2.5 mm²)flexible with cable end screw clamp terminals 1 0.00…0.01 in² (1…4 mm²)solid without cable end screw clamp terminals 2 0.00…0.01 in² (1…4 mm²)solid without cable end Tightening torque 10.62 lbf.in (1.2 N.m) screw clamp terminals Philips No 2 10.62 lbf.in (1.2 N.m) screw clamp terminals flat Ø 6 mm Control circuit voltage limits 0.1...0.25 Uc -40…158 °F (-40…70 °C) drop-out DC 0.7...1.25 Uc -40…140 °F (-40…60 °C) operational DC 1...1.25 Uc 140…158 °F (60…70 °C) operational DC Operating time 53...72 ms coil energisation and NO closing 16...24 ms coil de-energisation and NO opening 47...63 ms coil energisation and NC opening 15...25 ms coil de-energisation and NC closing Mechanical durability 30 Mcycles Maximum operating rate 180 cyc/mn Time constant 28 ms Inrush power in W 5.4 W 68 °F (20 °C)) Hold-in power consumption in W 5.4 W 68 °F (20 °C) Minimum switching voltage 17 V Minimum switching current 5 mA Non-overlap time 1.5 ms on energisation between NC and NO contact 1.5 ms on de-energisation between NC and NO contact Insulation resistance > 10 MOhm Mechanical robustness Shocks control relay open10 Gn for 11 ms IEC 60068-2-27 Shocks control relay closed15 Gn for 11 ms IEC 60068-2-27 Vibrations control relay open2 Gn, 5...300 Hz IEC 60068-2-6 Vibrations control relay closed4 Gn, 5...300 Hz IEC 60068-2-6 Maximum Height 3.03 in (77 mm) Maximum Width 1.77 in (45 mm) Maximum Depth 3.66 in (93 mm) Net Weight 1.28 lb(US) (0.58 kg) Environment Standards BS 4794 EN 60947-5 IEC 60947-5-1 NF C 63-140 VDE 0660 Product Certifications CSA UL IP degree of protection IP2x front face VDE 0106 Protective treatment TH IEC 60068 Ambient air temperature for operation -40…140 °F (-40…60 °C) 140…158 °F (60…70 °C) with derating Ambient Air Temperature for Storage -76…176 °F (-60…80 °C) Operating altitude 0...9842.52 ft (0...3000 m) Ordering and shipping details Category 22371 - RELAYS, CONTROL Discount Schedule I12 GTIN 03389110404203 Nbr. of units in pkg. 1 Package weight(Lbs) 18.38 oz (521 g) Returnability Yes Country of origin ID 2 |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |