| поискавой системы для электроныых деталей |
|
PFC500 датащи(PDF) 2 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
PFC500 датащи(HTML) 2 Page - Bel Fuse Inc. |
|
2 / 5 page ![]() 2 tech.support@psbel.com MODEL5 OUTPUT VOLTAGE ADJUSTMENT RANGE MAX. OUTPUT CURRENT2 LINE REGULATION LOAD REGULATION3 RIPPLE & NOISE % p-p4 INITIAL SETTING ACCURACY PFC500-1024G 24V 21.6V to 26.4V 21A 0.5% 0.2% 1% 23.88V to 24.12V PFC500-1028G1 28V 25.2V to 30.8V 17.9A 0.5% 0.2% 1% 27.86V to 28.14V PFC500-1048G1 48V 46.0V to 56.0V 10.4A 0.5% 0.5% 1% 47.52V to 48.48V NOTES: 1 Consult factory for availability of 28V and 48V units with DC input. 2 Output currents ratings are expressed with 300 LFM forced air. 3 Remote sense connected. See Application Note #P1 for load regulation when using the D option for 24V units. 4 Maximum peak to peak noise expressed as a percentage of output voltage, 20 MHz bandwidth. For ripple/noise on “D” option models, see options data. 5 Models without suffix G use the lead solder exemption PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Continuous input range. 85 264 VAC Input Frequency AC Input. 47 63 Hz Brown Out Protection Lowest AC input voltage that regulation is maintained with full rated loads. 85 VAC Hold-Up Time Over full AC input voltage range at full rated load. 20 ms Input Current 85 VAC at full rated load. 7.8 ARMS Input Protection Non-user serviceable internally located AC input line fuse, F10A, 250 V. Inrush Surge Current Internally limited by thermistor, one cycle, 25°C. 110 VAC 220 VAC 35 65 APK Power Factor Per EN61000-3-2. 0.98 W/VA Operating Frequency Switching frequency of main transformer. 100 kHz PARAMETER CONDITIONS / DESCRIPTION MIN NOM MAX UNITS Efficiency Full rated load, 110 VAC. 75 % Minimum loads PFC500-1024G PFC500-1028G PFC500-1048G 0.6 0.6 1.2 Amps Ripple and Noise Full load, 20 MHz bandwidth. See Model Selection Charts Output Power 300 LFM forced air cooling required for operation. See optional fan. Continuous power, multiple output models. 500 Watts Overshoot / Undershoot Output voltage overshoot/undershoot at turn-on. 0 V Regulation Without connection of remote sense. PFC500-1024G PFC500-1028G PFC500-1048G 0.8 0.7 1.0 % Transient Response Recovery time, to within 1% of initial set point due to a 50-100% load change, 3% max. deviation. 1 ms Turn-on Delay Time required for initial output voltage stabilization. 1 Sec Turn-on Rise Time Time required for output voltage to rise from 10% to 90%. 10 ms |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |