| поискавой системы для электроныых деталей |
|
ABC450 датащи(PDF) 3 Page - Bel Fuse Inc. |
|
|
|||||||||||||||||||||||||||||
ABC450 датащи(HTML) 3 Page - Bel Fuse Inc. |
|
3 / 10 page ![]() ABC450 Series 3 Asia-Pacific +86 755 298 85888 Europe, Middle East +353 61 225 977 North America +1 408 785 5200 © 2021 Bel Power Solutions & Protection BCD.00326_AH PARAMETER DESCRIPTION / CONDITION SPECIFICATIONS Output Voltage 5 to 48 V Output Power 3, 4 475 W for 24 V, 30 V models & 500 W for 48 V model only for 5 seconds max. 155 to 450 W Standby Output 5 5 VDC Fan Output 6 12 V Efficiency (Full Load) 120 VAC 24, 30 & 48 V models 12 & 15 V models 5 V model 88% 86% 83% typical 230 VAC 24, 30 & 48 V models 90% Hold Up Time 120 / 230 VAC 10 ms Power Factor 120 VAC 230 VAC 0.98 0.95 Line Regulation ± 0.5% Load Regulation ± 3% Transient Response <10%, 50% to 100% load change, 50 Hz, 50% duty cycle, 0.1 A/µs Recovery time < 5 ms Rise Time < 100 ms Set Point Tolerance ± 1% Output Voltage Adjustment V1 ± 3 % Over Voltage Protection Latch Type >114% Over Current Protection Hiccup type 120 to 150% Short Circuit Protection Short term, auto recovery Over Temperature Protection Automatic recovery 130°C primary heat sink Current Share Up to 2 supplies connected in parallel (optional) Cooling Convection 5 V model 12 & 15 V models 24, 30 & 48 V models 155 W 250 W 300 W With 420 LFM 5 V model 12 & 15 V models 24, 30 & 48 V models 275 W 450 W 450 W 3 Combined output power of main output, fan supply and standby supply shall not exceed max. power rating. 4 Derate output power linearly to 80% from 90 VAC to 80 VAC input. 5 Standby output voltage 5 V / 1.5 A (convection) / 2 A (420 LFM) with tolerance including set point accuracy, line & load regulation is +/-10%. Ripple and noise is less than 5%. 6 Fan supply output voltage 12V / 500 mA with tolerance including set point accuracy, line and load regulation is +/-30% and needs min. 1% load on main output to be within regulation band. Ripple and noise is less than 10%. PARAMETER DESCRIPTION / CONDITION Power Good Signal TTL signal goes high after main output is within regulation band, delay is 0.1 to 0.3 s Remote Sense Compensates for 200 mV drop Remote on/off To turn on PSU short remote pin to ground |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |