| поискавой системы для электроныых деталей |
|
TAS5036APFCR датащи(PDF) 33 Page - Texas Instruments |
|
|
|||||||||||||||||||||||||||||
TAS5036APFCR датащи(HTML) 33 Page - Texas Instruments |
|
33 / 62 page ![]() Serial Control Interface Register Definitions 27 SLES061B—November 2002—Revised January 2004 TAS5036A 3.4 System Control Register 1 (0x03) Table 3−5. System Control Register 1 D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 0 - - - - - - - Reserved - 0 - - - - - - Valid remains high during automute. - 1 - - - - - - Valid goes low during automute. - - 0 - - - - - Valid remains high during mute. - - 1 - - - - - Valid goes low during mute. - - - 0 - - - - Mute - - - 1 - - - - Normal mode - - - - 0 - - - Set error recovery delay at 6 µs - - - - 1 - - - Set error recovery delay at 47 µs - - - - - 0 - - Error recovery (forces error recovery initialization sequence) - - - - - 1 - - Normal mode - - - - - - 0 - Automute disabled - - - - - - 1 - Automute enabled - - - - - - - 0 Reserved 3.5 Error Recovery Register (0x04) Table 3−6. Error Recovery Register D7 D6 D5 D4 D3 D2 D1 D0 FUNCTION 1 1 − − − − − − Set to 11 under default conditions and when x00 is written into x1F 0 − − − − − − − If 0x84 is written into register 0x1F – Enable volume ramp up after an error recovery sequence is initiated by the ERR_RCVRY terminal or the I2C error recovery command (register X03 bit D2) 1 − − − − − − − If 0x84 is written into register 0x1F – Disable volume ramp up after an error recovery sequence is initiated by the ERR_RCVRY terminal or the I2C error recovery command (register X03 bit D2) − 0 − − − − − − If 0x84 is written into register 0x1F – Enable volume ramp up after error recovery sequence is initiated by register bits D5 – D0 of this register − 1 − − − − − − If 0x84 is written into register 0x1F – Enable volume ramp up after error recovery sequence is initiated by register bits D5 – D0 of this register − − 0 − − − − − Put channel 6 into error recovery mode − − − 0 − − − − Put channel 5 into error recovery mode − − − − 0 − − − Put channel 4 into error recovery mode − − − − − 0 − − Put channel 3 into error recovery mode − − − − − − 0 − Put channel 2 into error recovery mode − − − − − − − 0 Put channel 1 into error recovery mode − − 1 1 1 1 1 1 Normal operation |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |