| поискавой системы для электроныых деталей |
|
R3-TC2 датащи(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3-TC2 датащи(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 7 page ![]() MODEL: R3-TC2 R3-TC2 SPECIFICATIONS ES-8468 Rev.3 Page 1/7 http://www.m-system.co.jp/ Remote I/O R3 Series TEMPERATURE CONTROL MODULE Functions & Features • Two PID controllers • Universal input x 2 points, control output x 4 points, discrete input x 2 points, clamp-on current sensor input x 2 points • 2 universal inputs configurable to T/C, RTD, DC current or voltage independently • Discrete inputs usable to switch PID bank or operation mode • Control outputs configurable to MV, PV or alarm • Clamp-on current sensor input enables to detect heater wire break or over current • Auto tuning function • Minimum construction with an installation base (model: R3 -BS02), interface module and temperature controller module • Configurable with PC configurator (model: R3CON) • Mixed installation with other I/O modules 27.5 (1.08) 130 (5.12) mm (inch) 109 (4.29) MODEL: R3-TC2[1]S[2] ORDERING INFORMATION • Code number: R3-TC2[1]S[2] Specify a code from below for each [1] and [2]. (e.g. R3-TC2AS/Q) • Specify the specification for option code /Q (e.g. /C01) CONTROL LOOP 2: 2 loops [1] CONTROL OUTPUT A: 0 – 20 mA DC (Load resistance 500 Ω max.) Open-collector 2 points V: 0 – 10 V DC (Load resistance 2 kΩ max.) Open-collector 2 points P: 12 V pulse (Load resistance 600 Ω max.) Open-collector 2 points COMMUNICATION MODE S: Single [2] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating RELATED PRODUCTS • Modbus Interface Module (model: R3-NM3) (Not compatible with other Network modules) • PC configurator software (model: R3CON) Downloadable at M-System’s web site. A dedicated cable is required to connect the module to the PC. Please refer to the internet software download site or the users manual for the PC configurator for applicable cable types. • Clamp-on current sensor (model: CLSE) (Used for detecting the heater wire break) GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R3-BSx) Input, control output: M3 separable screw terminal (torque 0.5 N·m) Internal power: Via the Installation Base (model: R3-BSx) Screw terminal: Nickel-plated steel Isolation: Pv1 to Pv2 to CT1 or CT2 to Di1 or Di2 to MV1 or MV2 to Do1 or Do2 to internal bus or internal power CT Input waveform RMS sensing: Up to 15 % of 3rd harmonic content RUN indicator: Bi-color (red/green) LED; Red when the internal bus operates normally. ERR indicator: Bi-color (red/green) LED; Red at device error; Green in normal operating conditions. Loop status indicator (RUN1): Red LED; turns on when loop 1 operating Loop status indicator (AUTO1): Red LED; turns on during auto mode, turns off during manual mode at loop 1 Loop status indicator (ERR1): Red LED; turns on during error at loop 1 Loop status indicator (ALM1): Red LED; turns on when alarm |
Аналогичный номер детали - R3-TC2 |
|
Аналогичное описание - R3-TC2 |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |