  R3-PD16BS/Q Datasheet HTML 1Page - M-System Co.,Ltd. R3-PD16BS/Q Datasheet HTML 2Page - M-System Co.,Ltd. R3-PD16BS/Q Datasheet HTML 3Page - M-System Co.,Ltd. R3-PD16BS/Q Datasheet HTML 4Page - M-System Co.,Ltd. R3-PD16BS/Q Datasheet HTML 5Page - M-System Co.,Ltd. R3-PD16BS/Q Datasheet HTML 6Page - M-System Co.,Ltd. R3-PD16BS/Q Datasheet HTML 7Page - M-System Co.,Ltd. R3-PD16BS/Q Datasheet HTML 8Page - M-System Co.,Ltd.  
Zoom Inzoom in Zoom Outzoom out
 2 / 8 page
background image
MODEL: R3-PD16B
R3-PD16B SPECIFICATIONS
ES-8390 Rev.5 Page 2/8
http://www.m-system.co.jp/
OUTPUT SPECIFICATIONS
Output: Triac, 16 points
Isolation: Optical isolator
Common: All 16 points (4 terminals)
Common current: Max. 3.2 A per common
Rated load voltage: 100 – 240 V AC
Operational load voltage: 85 – 264 V AC
Maximum load current: 0.4 A per point
Maximum rush current: 6 A for 1 cycle or less time
Maximum leak current at OFF: ≤ 1.5 mA
(200 V AC , 60 Hz)
Maximum voltage drop at ON: ≤ 1.6 V RMS
Other features: Zero-cross function, CR absorber, no fuse
provided
INSTALLATION
Operating temperature: -10 to +55°C (14 to 131°F)
Operating humidity: 30 to 90 %RH (non-condensing)
Atmosphere: No corrosive gas or heavy dust
Mounting: Installation Base (model: R3-BSx)
Weight: 200 g (0.44 lb)
PERFORMANCE
Output ON time accuracy:
±10 % for 1 sec. or less setting;
±0.1 sec. for 1 sec. or more setting
Data allocation: 1
Current consumption: 140 mA
Response time: ≤ 0.1 sec. (delay)
Insulation resistance: ≥ 100 MΩ with 500 V DC
Dielectric strength: 1500 V AC @ 1 minute
(output to internal bus or internal power)
2000 V AC @ 1 minute (power input to FG; isolated on the
power supply module)
FUNCTIONS
■OUTPUT HOLD or OUTPUT OFF
In normal conditions, the module outputs the signal from
the preferred bus A.
When an error is detected, the output is switched to the
data from the bus B.
• Output Hold
If both are in error, the module holds the signal and stands
by until one of the communications recovers.
• Output OFF
If both are in error, the module outputs OFF signals and
stands by until one of the communications recovers.
At the startup, it outputs OFF until the communication is
established and normal data is received.



Html Pages

1 2 3 4 5 6 7 8


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com