| поискавой системы для электроныых деталей |
|
R3S-DAC16S/Q датащи(PDF) 1 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
R3S-DAC16S/Q датащи(HTML) 1 Page - M-System Co.,Ltd. |
|
1 / 9 page ![]() MODEL: R3S-DAC16 R3S-DAC16 SPECIFICATIONS ES-8933 Rev.4 Page 1/9 http://www.m-system.co.jp/ Remote I/O R3 Series DISCRETE INPUT OUTPUT MODULE (Di 8 points, Do 8 points, tension clamp terminal block) Typical Applications • Controls start/stop of field devices with ON/OFF control output • Simplifies signal hold circuit of field devices • Utilizing One-Shot Output reduces the load of PLC side. 27.5 (1.08) 130 (5.12) 120 (4.72) mm (inch) MODEL: R3S-DAC16[1][2] ORDERING INFORMATION • Code number: R3S-DAC16[1][2] Specify a code from below for each [1] and [2]. (e.g. R3S-DAC16W/Q) • Specify the specification for option code /Q (e.g. /C01) NO. OF CHANNELS 16: 16 points (8 input, 8 output) [1] COMMUNICATION MODE S: Single W: Dual [2] OPTIONS blank: none /Q: With options (specify the specification) SPECIFICATIONS OF OPTION: Q COATING (For the detail, refer to M-System's web site.) /C01: Silicone coating /C02: Polyurethane coating /C03: Rubber coating CAUTION • This unit is not designed to be used with the following types of interface modules (models: R3-NC2, R3-NEIP1, R3- NFx, R3-NLx). • Output completion status data is compatible with interface modules (models: R3-NC1, R3-NC3, R3-NDx, R3-NE1, R3- NFL1, R3-NM1, R3-NM4, R3-NP1) of firmware version V2.00 or higher, and interface modules (models: R3-NM3, R3- NML3) of firmware version V1.00 or higher. GENERAL SPECIFICATIONS Connection Internal bus: Via the Installation Base (model: R3-BSx) I/O: Separable tension clamp terminal (applicable wire size: 0.2 to 1.5 mm2, stripped length 10 mm) Internal Power: Via the Installation Base (model: R3-BSx) Isolation: Input to output to internal bus or internal power Output mode setting: One-Shot Output Mode, ON/OFF Control Output Mode, Continuance Output Mode selectable with DIP switch Data length Setting: 8bit, 4bit selectable with DIP switch (For ON/OFF Control Output Mode only) One-shot ON time setting: 0.1 to 25.6 sec. selectable with DIP switch ON/OFF control output setting: Swappable its pair with DIP switch. Output hold setting: Setting for communication error with side DIP SW RUN indicator: Bi-color (red/green) LED; Red when the bus A operates normally; Green when the bus B operates normally; Amber when both buses operate normally. ERR indicator: Bi-color (red/ green) LED; Green in normal operating conditions Red with the abnormal configuration Status indicator: Red LED; 1 to 8: Intput status, turns on with input ON. 9 to 16: Output status, turns on with output ON. Di read rate setting: 1 / 5 / 10 / 20 / 50 / 70 / 100 / 200 msec. selectable with DIP SW INPUT SPECIFICATIONS Number of input: 8 points Isolation: Optical isolator Input resistance: Approx. 4.4 kΩ Common: Positive or negative (NPN/PNP) common per 8 points (2 terminals) ON voltage/current: ≥ 11 V, ≥ 2.5 mA OFF voltage/current: ≤ 6 V, ≤ 1.3 mA ■ Dry Contact input |
Аналогичный номер детали - R3S-DAC16S/Q |
|
Аналогичное описание - R3S-DAC16S/Q |
|
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |