Back Button ACE25AA800GFMTH Datasheet HTML 24Page - ACE Technology Co., LTD. ACE25AA800GFMTH Datasheet HTML 25Page - ACE Technology Co., LTD. ACE25AA800GFMTH Datasheet HTML 26Page - ACE Technology Co., LTD. ACE25AA800GFMTH Datasheet HTML 27Page - ACE Technology Co., LTD. ACE25AA800GFMTH Datasheet HTML 28Page - ACE Technology Co., LTD. ACE25AA800GFMTH Datasheet HTML 29Page - ACE Technology Co., LTD. ACE25AA800GFMTH Datasheet HTML 30Page - ACE Technology Co., LTD. ACE25AA800GFMTH Datasheet HTML 31Page - ACE Technology Co., LTD. ACE25AA800GFMTH Datasheet HTML 32Page - ACE Technology Co., LTD. Next Button
Zoom Inzoom in Zoom Outzoom out
 28 / 50 page
background image
ACE25AA800G
Serial NOR Flash Memory 3.0V Multi I/O with 4KB,32KB & 64KB Sector/Block Erase
VER 1.1
28
Read Manufacture ID/ Device ID (REMS) (90H)
The Read Manufacturer/Device ID command is an alternative to the Release from Power-Down / Device
ID command that provides both the JEDEC assigned Manufacturer ID and the specific Device ID. The
command is initiated by driving the CS# pin low and shifting the command code “90H” followed by a 24-bit
address (A23-A0) of 000000H. After which, the Manufacturer ID and the Device ID are shifted out on the
falling edge of SCLK with most significant bit (MSB) first is shown in Figure 26. If the 24-bit address is
initially set to 000001H, the Device ID will be read first.
Continuous Read Mode Reset (CRMR) (FFH)
The Dual/Quad I/O Fast Read operations, “Continuous Read Mode” bits (M7-0) are implemented to
further reduce command overhead. By setting the (M7-0) to AXH, the next Dual/Quad I/O Fast Read
operations do not require the BBH/EBH/E7H command code.
Because the ACE25AA800G has no hardware reset pin, so if Continuous Read Mode bits are set to
“AXH”, the ACE25AA800G will not recognize any standard SPI commands. So Continuous Read Mode
Reset command will release the Continuous Read Mode from the “AXH” state and allow standard SPI
command to be recognized. The command sequence is shown in Figure 27.
Figure26. Read ID Sequence Diagram
Figure27. Continuous Read Mode Reset Sequence Diagram



Html Pages

1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 27 28 29 30 31 32 33 34 35 36 37 38 39 40 41 42 43 44 45 46 47 48 49 50


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com