| поискавой системы для электроныых деталей |
|
MSP6 датащи(PDF) 3 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
MSP6 датащи(HTML) 3 Page - M-System Co.,Ltd. |
|
3 / 5 page ![]() MODEL: MSP6 MSP6 SPECIFICATIONS ES-4853 Rev.19 Page 3/5 http://www.m-system.co.jp/ INSTALLATION Power consumption •AC: 25 VA •DC: 0.6 A (Current is approx. 1.5 times as high as the above figure during the motor startup) Operating temperature: -5 to +55°C (23 to 131°F) Operating humidity: 30 to 85 %RH (non-condensing) Vibration •Sweep endurance test Acceleration: 2 G (19.6 m/s2) Frequency: 10 to 1000 Hz Cycle: 20 cycles Rate: 1 Oct./min. Endurance: approx. 4 hr. 30 min. Direction: X, Y, Z Mounting position: All directions However, DO NOT mount the actuator with its output stem or cable connector facing upward if the actuator is to be exposed to dripping water. Weight DC powered: 3.7 kg (8.16 lb) AC powered: 3.8 kg (8.38 lb) Add 0.7 kg (1.54 lb) for the terminal box. PERFORMANCE Resolution: 1/1000 or 0.02 mm, whichever is greater, with a deadband of 0.1 % Insulation resistance •AC powered (100 V AC, 200 V AC): ≥ 100 MΩ with 500 V DC (signal or metallic housing to power) ≥ 100 MΩ with 100 V DC (signal to metallic housing) •AC powered (24 V AC): ≥ 100 MΩ with 100 V DC (signal or metallic housing to power) •DC powered (24 V DC): ≥ 100 MΩ with 100 V DC (signal or power to metallic housing) Dielectric strength •AC powered (100 V AC, 200 V AC): 1500 V AC @ 1 minute (signal or metallic housing to power) 100 V AC @ 1 minute (signal to metallic housing) •AC powered (24 V AC): 1500 V AC @ 1 minute (signal or metallic housing to power) •DC powered (24 V DC): 100 V AC @ 1 minute (signal or power to metallic housing) STANDARDS & APPROVALS EU conformity: EMC Directive EMI EN 61000-6-4 EMS EN 61000-6-2 Low Voltage Directive EN 61010-1 Measurement Category II (Full-open/-closed signal) Pollution Degree 2 Full-open/-closed signal to other, power or metallic housing: Reinforced insulation (125 V) RoHS Directive EN 50581 TERMINOLOGY • Overload (Lock) Protection The Mini-Top Series is equipped with a protection circuit against overload caused by for example the valve catching an alien substance. When an overload is detected, the Mini-Top stops supplying power to the motor and the status LED blinks in 0.5 sec. intervals. The protection is reset automatically with applying opposite- direction input signal or turning the power off and restarting. • Restarting Timer The Mini-Top Series is equipped with a timer circuit which gives an interval period (0 – 10 seconds) between stop- restart actions to prevent the motor and other internal components from overheating. It is recommended to set a long restarting time when the ambient temperature and/or the temperature of flow material is high. • Electronic Limiter This model is equipped with electronic limiters in order to prevent mechanical locks when the input goes below 0 % or above 100 %. Limiters are set at approx. -0.5 % for the full-closed side, approx. 100.5 % for the full-open side. • Seal-Spring The Mini-top Series incorporates a seal-spring to maintain the sealing pressure when the valve is fully closed. The standard spring has 0.5 – 1 mm (.02” – .04”) flexibility to facilitate the full-closed adjustment. |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |