| поискавой системы для электроныых деталей |
|
B6UB датащи(PDF) 2 Page - M-System Co.,Ltd. |
|
|
|||||||||||||||||||||||||||||
B6UB датащи(HTML) 2 Page - M-System Co.,Ltd. |
|
2 / 7 page ![]() MODEL: B6U-B B6U-B SPECIFICATIONS ES-7453 Rev.29 Page 2/7 http://www.m-system.co.jp/ PACKAGE INCLUDES... • Mounting screws Bolt (M8 x 15): 4 pcs. Spring washer for M8: 4 pcs. Material: Stainless steel 304 • Mounting bracket set (option) Mounting bracket: 1 pce. M10 U-bolt: 2 pcs. Nut for M10: 4 pcs. Spring washer for M10: 4 pcs. Material: Stainless steel 304 Applicable pipe: 1 1/2” min.; 2” max. • LCD Angle Change Adaptor (for optional LCD display): Adaptor plate: 1 pce. Flat head screw (M4 x 10): 2 pcs. GENERAL SPECIFICATIONS Degree of protection: NEMA 4X, IP66/IP67 Wiring conduit: See ‘Ordering information.’ Electrical connection: M3.5 screw terminals (torque 0.8 N·m) Materials Transmitter housing: Flame-resistant resin (black) Screw terminals: Nickel-plated brass Enclosure: Diecast aluminium standard or stainless steel casting (equivalent to type 316); silver epoxy resin coating Isolation: Input to output to outdoor enclosure Burnout (T/C, RTD, Potentiometer & Resistance): Upscale, downscale or no burnout selectable (standard: upscale); Also detects wire breakdown and overrange input exceeding the electrical design limit for DC input. Cold Junction Compensation (thermocouple input): CJC sensor incorporated User-configurable items: · Input sensor type · Number of wires (RTD & resistance) · Input range · Inverted output · Burnout · Damping time (via HART only, standard: 0) · Sensor calibration (via HART only) · Output calibration · Special linearization data (via HART only) · HART communication mode HART COMMUNICATION Protocol: HART communication protocol HART address range: 0 – 15 (factory set to 0) Transmission speed: 1200 bps Digital current: Approx. 1 mAp-p when communicating Character format: 1 Start Bit, 8 Data Bits, 1 Odd Parity Bit, 1 Stop Bit Distance: 1.5 km (0.9 miles) HART communication mode: Master-Slave Mode and Burst Mode (factory set to Master-Slave) HART network mode: Point-to-Point Mode and Multi-drop Mode; automatically set to Multi-drop Mode when the address is set to other than 0. LCD DISPLAY (option) Features: · Setting and display of input signals, engineering units and the transmitter operating status, etc. · Removable while the module is powered. Display size: 36 × 20 mm (1.42” × 0.79”) Characters Color: Black Format: • 2 rows of 5 alphanumeric characters: Top row: 7.4 mm high; Bottom row: 6.5 mm high, • Status indicators and engineering units For detail of the LCD panel indication, refer to the instruction manual. Display range: -99999 to 99999 Decimal point: In top row Read rate: 150 msec. Back light: None INPUT SPECIFICATIONS The input type is factory-set to K thermocouple, and the input range to 0 to 100°C. See Table 1 for the available input type, the minimum span, and the maximum range. ■ DC mV & V Input resistance: ≥ 1 MΩ ■ Thermocouple Input resistance: ≥ 1 MΩ Burnout sensing: 130 nA ±10 % ■ RTD (2-wire, 3-wire or 4-wire) Input resistance: ≥ 1 MΩ Allowable leadwire resistance: Max. 20 Ω per wire ■ Resistance (2-wire, 3-wire or 4-wire) Excitation: 0.2 mA ±10 % Allowable leadwire resistance: Max. 20 Ω per wire ■ Potentiometer Excitation: 0.2 mA ±10% Allowable leadwire resistance: Max. 20 Ω per wire |
|
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |