поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

MLCE6.5AE3 датащи(PDF) 3 Page - Microsemi Corporation

номер детали MLCE6.5AE3
подробное описание детали  1500 Watt Low Capacitance Transient Voltage Suppressor
PDF  5 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  MICROSEMI [Microsemi Corporation]
домашняя страница  http://www.microsemi.com
Logo MICROSEMI - Microsemi Corporation

MLCE6.5AE3 датащи(HTML) 3 Page - Microsemi Corporation

  MLCE6.5AE3 Datasheet HTML 1Page - Microsemi Corporation MLCE6.5AE3 Datasheet HTML 2Page - Microsemi Corporation MLCE6.5AE3 Datasheet HTML 3Page - Microsemi Corporation MLCE6.5AE3 Datasheet HTML 4Page - Microsemi Corporation MLCE6.5AE3 Datasheet HTML 5Page - Microsemi Corporation  
Zoom Inzoom in Zoom Outzoom out
 3 / 5 page
background image
RF01009, Rev. B (5/7/13)
©2013 Microsemi Corporation
Page 3 of 5
MLCE6.5 – MLCE170A
SYMBOLS & DEFINITIONS
Symbol
Definition
I(BR)
Breakdown Current: The current used for measuring breakdown voltage V(BR).
ID
Standby Current: The current at the rated standoff voltage VWM.
IF
Forward Current: The forward current dc value, no alternating component.
IPP
Peak Impulse Current: The peak current during the impulse.
PPP
Peak Pulse Power: The peak power dissipation resulting from the peak impulse current IPP.
VC
Clamping Voltage: The maximum clamping voltage at specified IPP (peak pulse current) at the specified pulse
conditions.
V(BR)
Minimum Breakdown Voltage: The minimum voltage the device will exhibit at a specified current.
VWM
Working Standoff Voltage: The maximum peak voltage that can be applied over the operating temperature range.
ELECTRICAL CHARACTERISTICS @ 25 ºC unless otherwise stated
MICROSEMI
Part Number
Working
Stand-Off
Voltage
VWM
(Note 1)
Volts
Breakdown Voltage
V(BR)
@ I(BR)
Volts
Maximum
Stanby
Current
ID @ VWM
µA
Maximum
Clamping
Voltage
VC @ IPP
Volts
Maximum
Peak Pulse
Current
IPP
Amps
Maximum
Capacitance
C @ 0 Volts,
f = 1 MHz
pF
Working
Inverse
Blocking
Voltage
V WIB
Volts
Inverse
Blocking
Leakage
Current
IIB
µA
Peak
Inverse
Blocking
Voltage
VPIB
Volts
MIN
MAX
mA
MLCE6.5A
MLCE7.0A
6.5
7.0
7.22
7.78
7.98
8.60
10
10
1000
500
11.2
12.0
100
100
100
100
75
75
10
10
100
100
MLCE7.5A
MLCE8.0A
7.5
8.0
8.33
8.89
10.2
9.83
10
1
250
100
12.9
13.6
100
100
100
100
75
75
10
10
100
100
MLCE8.5A
MLCE9.0A
8.5
9.0
9.44
10.0
10.4
11.1
1
1
50
10
14.4
15.4
100
97
100
100
75
75
10
10
100
100
MLCE10A
MLCE11A
10
11
11.1
12.2
12.3
13.5
1
1
5
5
17.0
18.2
88
82
100
100
75
75
10
10
100
100
MLCE12A
MLCE13A
12
13
13.3
14.4
14.7
15.9
1
1
5
5
19.9
21.5
75
70
100
100
75
75
10
10
100
100
MLCE14A
MLCE15A
14
15
15.6
16.7
17.2
18.5
1
1
5
5
23.2
24.4
65
61
100
100
75
75
10
10
100
100
MLCE16A
MLCE17A
16
17
17.8
18.9
19.7
20.9
1
1
5
5
26.0
27.6
57
54
100
100
75
75
10
10
100
100
MLCE18A
MLCE20A
18
20
20.0
22.2
22.1
24.5
1
1
5
5
29.2
32.4
51
46
100
100
75
75
10
10
100
100
MLCE22A
MLCE24A
22
24
24.4
26.7
26.9
29.5
1
1
5
5
35.5
38.9
42
39
100
100
75
75
10
10
100
100
MLCE26A
MLCE28A
26
28
28.9
31.1
31.9
34.4
1
1
5
5
42.1
45.5
36
33
100
100
75
75
10
10
100
100
MLCE30A
MLCE33A
30
33
33.3
36.7
36.8
40.6
1
1
5
5
48.4
53.3
31
28.1
100
100
75
75
10
10
100
100
MLCE36A
MLCE40A
36
40
40.0
44.4
44.2
49.1
1
1
5
5
58.1
64.5
25.8
23.3
100
100
75
75
10
10
100
100
MLCE43A
MLCE45A
43
45
47.8
50.0
52.8
55.3
1
1
5
5
69.4
72.7
21.6
20.6
100
100
150
150
10
10
200
200
MLCE48A
MLCE51A
48
51
53.3
56.7
58.9
62.7
1
1
5
5
77.4
82.4
19.4
18.2
100
100
150
150
10
10
200
200
MLCE54A
MLCE58A
54
58
60.0
64.4
66.3
71.2
1
1
5
5
87.1
93.6
17.2
16.0
100
100
150
150
10
10
200
200
MLCE60A
MLCE64A
60
64
66.7
71.1
73.7
78.6
1
1
5
5
96.8
103
15.5
14.6
90
90
150
150
10
10
200
200
MLCE70A
MLCE75A
70
75
77.8
83.3
86.0
92.1
1
1
5
5
113
121
13.3
12.4
90
90
150
150
10
10
200
200
MLCE80A
MLCE90A
80
90
88.7
100
98.0
111
1
1
5
5
129
146
11.6
10.3
90
90
150
300
10
10
200
200
MLCE100A
MLCE110A
100
110
111
122
123
135
1
1
5
5
162
178
9.3
8.4
90
90
300
300
10
10
200
400
MLCE120A
MLCE130A
120
130
133
144
147
159
1
1
5
5
193
209
7.8
7.2
90
90
300
300
10
10
400
400
MLCE150A
MLCE160A
150
160
167
178
185
197
1
1
5
5
243
259
6.2
5.8
90
90
300
300
10
10
400
400
MLCE170A
170
189
209
1
5
275
5.4
90
300
10
400
NOTE 1: TVS are normally selected according to the reverse “standoff voltage” (VWM) which should be equal to or greater than the dc or continuous
peak operating voltage level.



Html Pages

1 2 3 4 5


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp
Russian : Alldatasheetru.com  |   Korean : Alldatasheet.co.kr  |   Spanish : Alldatasheet.es  |   French : Alldatasheet.fr  |   Italian : Alldatasheetit.com
Portuguese : Alldatasheetpt.com  |   Polish : Alldatasheet.pl  |   Vietnamese : Alldatasheet.vn
Indian : Alldatasheet.in  |   Mexican : Alldatasheet.com.mx  |   British : Alldatasheet.co.uk  |   New Zealand : Alldatasheet.co.nz
Family Site : ic2ic.com  |   icmetro.com