42 / 132 page ![]() LTM4681 42 Rev. 0 For more information www.analog.com OPERATION Global addressing provides a means of the PMBus master to address all LTM4681 devices on the bus. The LTM4681 global address is fixed 0x5A (7-bit) or 0xB4 (8-bit) and cannot be disabled. Commands sent to the global address act the same as if PAGE is set to a value of 0xFF. Commands sent are written to both channels simultaneously. Global command 0x5B (7-bit) or 0xB6 (8-bit) is paged and allows channel specific command of all LTM4681 devices on the bus. Other ADI device types may respond at one or both of these global addresses. Reading from global addresses is strongly discouraged. Device addressing provides the standard means of the PMBus master communicating with a single instance of an LTM4681. The value of the device address is set by a combination of the ASEL_nn configuration pin and the MFR_ ADDRESS command. When this addressing means is used, the PAGE command determines the channel being acted upon. Device addressing can be disabled by writing a value of 0x80 to the MFR_ADDRESS. Rail addressing provides a means for the bus master to simultaneously communicate with all channels connected together to produce a single output voltage (PolyPhase). While similar to global addressing, the rail address can be dynamically assigned with the paged MFR_RAIL_ ADDRESS command, allowing for any logical grouping of channels that might be required for reliable system control. Reading from rail addresses is also strongly discouraged. All four means of PMBus addressing require the user to employ disciplined planning to avoid addressing conflicts. Communication to LTM4681 devices at global and rail addresses should be limited to command write operations. RESPONSES TO VOUT AND IIN/IOUT FAULTS VOUT OV and UV conditions are monitored by compara- tors. The OV and UV limits are set in three ways: n As a Percentage of the VOUT if Using the Resistor Configuration Pins n In NVM if Either Programmed at the Factory or Through the GUI n By PMBus Command The IIN and IOUT overcurrent monitors are performed by ADC readings and calculations. Thus these values are based on average currents and can have a time latency of up to tCONVERT. The IOUT calculation accounts for the DCR and their temperature coefficient. The input current is equal to the voltage measured across the RSENSEn resis- tor divided by the resistors value as set with the MFR_ IIN_CAL_GAIN command. If this calculated input current exceeds the IN_OC_WARN_LIMIT the ALERT_nn pin is pulled low and the IIN_OC_WARN bit is asserted in the STATUS_INPUT command. The digital processor within the LTM4681 provides the ability to ignore the fault, shut down and latch off or shut down and retry indefinitely (hiccup). The retry interval is set in MFR_RETRY_ DELAY and can be from 120ms to 83.88 seconds in 1ms increments. The shutdown for OV/UV and OC can be done immediately or after a user selectable deglitch time. Output Overvoltage Fault Response A programmable overvoltage comparator (OV) guards against transient overshoots as well as long-term over- voltages at the output. In such cases, the top MOSFET is turned off and the bottom MOSFET is turned on. However, the reverse output current is monitored while device is in OV fault. When it reaches the limit, both top and bottom MOSFETs are turned off. The top and bot- tom MOSFETs will keep their state until the overvoltage condition is cleared regardless of the PMBus VOUT_OV_ FAULT_RESPONSE command byte value. This hardware level fault response delay is typically 2µs from the over- voltage condition to BG asserted high. Using the VOUT_ OV_FAULT_RESPONSE command, the user can select any of the following behaviors: n OV Pull-Down Only (OV Cannot Be Ignored) n Shut Down (Stop Switching) Immediately—Latch Off n Shut Down Immediately—Retry Indefinitely at the Time Interval Specified in MFR_RETRY_DELAY Either the Latch Off or Retry fault responses can be de- glitched in increments of (0-7) • 10µs. See Table 14. |
|
ссылки URL |
| Вашему бизинису помогли Аллдатащит? [ DONATE ] |
Что такое Аллдатащит | реклама | контакт | Конфиденциальность | Ссылка на техническое описание | обмен ссыками | поиск по производителю All Rights Reserved©Alldatasheet.com |
| Russian : Alldatasheetru.com | Korean : Alldatasheet.co.kr | Spanish : Alldatasheet.es | French : Alldatasheet.fr | Italian : Alldatasheetit.com Portuguese : Alldatasheetpt.com | Polish : Alldatasheet.pl | Vietnamese : Alldatasheet.vn Indian : Alldatasheet.in | Mexican : Alldatasheet.com.mx | British : Alldatasheet.co.uk | New Zealand : Alldatasheet.co.nz |
|
Family Site : ic2ic.com |
icmetro.com |