поискавой системы для электроныых деталей
  Russian  ▼
ALLDATASHEETRU.COM

X  

FMB01 датащи(PDF) 3 Page - Carlo Gavazzi Holding AG

номер детали FMB01
подробное описание детали  Timers Multifunction Type FMB01
PDF  4 Pages
Scroll/Zoom Zoom In 100%  Zoom Out
производитель  CARLOGAVAZZI [Carlo Gavazzi Holding AG]
домашняя страница  https://gavazziautomation.com/
Logo CARLOGAVAZZI - Carlo Gavazzi Holding AG

FMB01 датащи(HTML) 3 Page - Carlo Gavazzi Holding AG

  FMB01 Datasheet HTML 1Page - Carlo Gavazzi Holding AG FMB01 Datasheet HTML 2Page - Carlo Gavazzi Holding AG FMB01 Datasheet HTML 3Page - Carlo Gavazzi Holding AG FMB01 Datasheet HTML 4Page - Carlo Gavazzi Holding AG  
Zoom Inzoom in Zoom Outzoom out
 3 / 4 page
background image
Specifications are subject to change without notice (21.03.08)
3
FMB01
Function Id - Double interval
Reset and Gate inputs working mode
If Reset contact is closed the relay is released and timing is
reset. Nothing else happens until Reset is released.
If Gate contact is closed the timing operation is freezed.
When it is released, if timing was in progress, it goes on
from the point reached at the moment of closing the Gate.
Function Rb - Symmetrical Recycler OFF first
Reset and Gate inputs working mode
If Reset contact is closed the function is interrupted, the
relay is released and timing is reset. Nothing else happens
until Reset is released.
If Gate contact is closed while recycling, the timing opera-
tion is freezed and the output is kept at the state it was
when Gate has been closed. When it is released, timing
goes on from the point reached at the moment of closing
the Gate.
Operating Diagrams
T
Powersupply
LED“POWER”
Triggerinput
T
T
T
T
RelaysON
T
Powersupply
LED“POWER”
Triggerinput
T
T
T
RelaysON
T
Powersupply
LED“POWER”
Triggerinput
T
T
T
T
RelaysON
Range and operation mode selection
Function Op - Delay ON Operate
Reset and Gate inputs working mode
If Reset contact is closed the relay is released and timing is
reset. Nothing else happens until Reset is released.
If Gate contact is closed the timing operation is freezed.
When it is released, if timing was in progress, it goes on
from the point reached at the moment of closing the Gate.
Powersupply
T
LED“POWER”
Triggerinput
RelaysON
T
Operating mode display window
Operating mode selector
(function Op, Rb, R, Id, Dr, In, Io)
Scale range display windows
Time unit selector (0.1s, sec, 10sec, min, etc.)
Time setting knob (set time)
Power indicator (green)
Time range selector 12 and 30 at full scale
Output indicator (yellow)
(Flashes when timer operates;
on when timer stops operating)
Time unit display window
Function R - Symmetrical Recycler ON first
Reset and Gate inputs working mode
If Reset contact is closed the function interrupted, the relay
is released and timing is reset. Nothing else happens until
Reset is released.
If Gate contact is closed while recycling, the timing opera-
tion is freezed and the output is kept at the state it was
when Gate has been closed. When it is released, timing
goes on from the point reached at the moment of closing
the Gate.



Html Pages

1 2 3 4


датащи скачать

Go To PDF Page


ссылки URL



Вашему бизинису помогли Аллдатащит?  [ DONATE ] 

Что такое Аллдатащит   |   реклама   |   контакт   |   Конфиденциальность   |   Ссылка на техническое описание    |   обмен ссыками   |   поиск по производителю
All Rights Reserved©Alldatasheet.com


Mirror Sites
English : Alldatasheet.com  |   English : Alldatasheet.net  |   Chinese : Alldatasheetcn.com  |   German : Alldatasheetde.com  |   Japanese : Alldatasheet.jp